Your browser doesn't support javascript.
loading
Experiencia inicial con la extracción de electrodos de marcapasos y desfibrilador asistida con láser excimer / Initial experience with excimer laser-assisted pacemaker and defibrillator lead extraction
Mosquera, Víctor X; Pérez-Álvarez, Luisa; Ricoy-Martínez, Enrique; Mosquera-Pérez, Ignacio; Castro-Beiras, Alfonso; Cuenca-Castillo, José J.
Afiliação
  • Mosquera, Víctor X; Complejo Hospitalario Universitario de A Coruña. A Coruña. España
  • Pérez-Álvarez, Luisa; Complejo Hospitalario Universitario de A Coruña. A Coruña. España
  • Ricoy-Martínez, Enrique; Complejo Hospitalario Universitario de A Coruña. A Coruña. España
  • Mosquera-Pérez, Ignacio; Complejo Hospitalario Universitario de A Coruña. A Coruña. España
  • Castro-Beiras, Alfonso; Complejo Hospitalario Universitario de A Coruña. A Coruña. España
  • Cuenca-Castillo, José J; Complejo Hospitalario Universitario de A Coruña. A Coruña. España
Rev. esp. cardiol. (Ed. impr.) ; 64(9): 824-827, sept. 2011. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-90874
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
La extracción de electrodos de marcapasos y/o desfibriladores de larga evolución puede ser una técnica exigente. Presentamos los resultados de la extracción asistida por láser excimer de los primeros 44 electrodos en 25 pacientes, con una mediana de tiempo de electrodo implantado de 7 (2-20) años. Las indicaciones para la extracción fueron fractura de electrodo en 17 casos, decúbito de bolsa en 4, bacteriemia en 2 y endocarditis sobre electrodo en 2 casos. Se logró la extracción completa de 43 electrodos (97,7%), mientras que en 1 caso se abandonó la porción distal de menos de 4 cm del electrodo. No se produjo mortalidad intrahospitalaria. El láser excimer se presenta como una alternativa segura y eficaz para la extracción de electrodos de marcapasos o desfibrilador, con resultados excelentes en nuestra serie (AU)
ABSTRACT
Explantation of chronically implanted pacemaker or defibrillator leads can be technically demanding. We present the results of the first 44 leads extracted with excimer laser sheaths in 25 patients with a median lead implantation time of 7 years (range 2 to 20 years). Indications for extraction were lead fracture in 17 patients, pocket infection in 4, septicemia in 2, and lead endocarditis in 2 cases. Complete extraction was achieved in 43 leads (97.7%), while the lead tip (<4cm) was abandoned in 1 case. There was no in-hospital mortality. The excimer laser-assisted system is a safe and efficient alternative for pacemaker and defibrillator lead extraction. This technology has resulted in excellent outcomes in our series, allowing us to treat remarkably difficult cases (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Marca-Passo Artificial / Desfibriladores Implantáveis / Eletrodos / Eletrodos Implantados Limite: Adolescente / Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cardiol. (Ed. impr.) Ano de publicação: 2011 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario Universitario de A Coruña/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Marca-Passo Artificial / Desfibriladores Implantáveis / Eletrodos / Eletrodos Implantados Limite: Adolescente / Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cardiol. (Ed. impr.) Ano de publicação: 2011 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario Universitario de A Coruña/España
...