Your browser doesn't support javascript.
loading
Respostas cardiovasculares agudas no treinamento de força conduzido em exercícios para grandes e pequenos grupamentos musculares / Acute cardiovascular responses in strenght training conducted in exercises for large and small muscular groups
D'Assunção, Welton; Daltro, Marcelo; Simão, Roberto; Polito, Marcos; Monteiro, Walace.
Afiliação
  • D'Assunção, Welton; Universidade Gama Filho. CEPAC. Rio de Janeiro, RJ. BR
  • Daltro, Marcelo; Universidade Gama Filho. CEPAC. Rio de Janeiro, RJ. BR
  • Simão, Roberto; Universidade Federal do Rio de Janeiro. Escola de Educação Física e Desportos. Rio de Janeiro. BR
  • Polito, Marcos; Universidade Gama Filho. CEPAC. Rio de Janeiro, RJ. BR
  • Monteiro, Walace; Instituto de Ciências da Atividade Física da Aeronáutica. Laboratório de Fisiologia do Exercício. Rio de Janeiro, RJ. BR
Rev. bras. med. esporte ; Rev. bras. med. esporte;13(2): 118-122, mar.-abr. 2007. graf, tab
Article em En, Pt | LILACS | ID: lil-472179
Biblioteca responsável: BR14.1
RESUMO
O objetivo deste estudo foi comparar o comportamento da pressão arterial sistólica (PAS), diastólica (PAD), freqüência cardíaca (FC) e duplo produto (DP) durante a execução unilateral de três séries de 10RM em dois exercícios envolvendo grupamentos musculares distintos. Participaram 18 homens normotensos (22,4 ± 2,7 anos; 76,2 ± 9,8kg; 175,4 ± 6,0cm) experientes em exercícios resistidos. Os voluntários foram submetidos ao procedimento experimental em quatro dias não consecutivos. No primeiro dia, aplicaram-se testes de 10RM nos exercícios rosca bíceps com haltere (RB) e cadeira extensora (CE). Após 48 horas, foi realizado um reteste de 10RM. Posteriormente à obtenção das cargas, realizaram-se três séries de 10RM nos exercícios selecionados. O ritmo de execução das séries em ambos os exercícios foi controlado por um metrônomo, estabelecendo-se um tempo de dois segundos para cada uma das fases excêntrica e concêntrica. A FC foi aferida por cardiofreqüencímetro e a PAS e PAD, pelo método auscultatório. A ANOVA de duas entradas com medidas repetidas, seguida do teste post-hoc de Tukey, não encontrou diferenças (p > 0,05) entre as respostas cardiovasculares nos diferentes exercícios. Contudo, verificaram-se diferenças significativas (p < 0,05) para PAS intra-exercícios. Dessa forma, ao menos no presente estudo, a massa muscular envolvida nos exercícios de força não influenciou as respostas cardiovasculares agudas em normotensos treinados.
ABSTRACT
The aim of this study was to compare the behavior of the systolic blood pressure (SBP); diastolic blood pressure (DBP); heart rate (HR) and double product (DP) during the unilateral performance of three sets of 10RM in two exercises involving distinct muscular groups. Eighteen normotense men (22.4 ± 2.7 years; 76.2 ± 9.8 kg; 175.4 ± 6.0 cm) experienced in resisted exercises participated in the study. The volunteers were submitted to the experimental procedure in four non-consecutive days. On the first day, the 10RM tests were applied in the biceps curls with dumbbells (BC) and extensor bench (SB). After 48 hours, a re-test of 10RM was performed. After the loads were obtained, three sets of 10RM were performed in the selected exercises. The performance rhythm in both exercises was controlled by a metronome, with an established time of two seconds for each of the eccentric and concentric phases. The HR was measured though a cardiofrequency meter and the SBP and the DBP through the auscultatory method. The two-way ANOVA with repeated measurements, followed by the post-hoc test by Tukey did not find differences (p > 0.05) for intra-exercises SBP. Therefore, at least in the present study, the muscular mass involved in the strength training did not influence the acute cardiovascular responses in trained normotensive subjects.
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Fatores de Tempo / Análise de Variância / Treinamento Resistido / Pressão Arterial / Frequência Cardíaca Limite: Humans / Male Idioma: En / Pt Revista: Rev. bras. med. esporte Assunto da revista: MEDICINA ESPORTIVA Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS Assunto principal: Fatores de Tempo / Análise de Variância / Treinamento Resistido / Pressão Arterial / Frequência Cardíaca Limite: Humans / Male Idioma: En / Pt Revista: Rev. bras. med. esporte Assunto da revista: MEDICINA ESPORTIVA Ano de publicação: 2007 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil