Your browser doesn't support javascript.
loading
Congenital toxoplasmosis: evaluation of serological methods for the detection of anti-Toxoplasma gondii IgM and IgA antibodies
Rodrigues, I. M. X; Castro, A. M; Gomes, M. B. F; Amaral, W. N; Avelino, M. M.
Afiliação
  • Rodrigues, I. M. X; Universidade Federal de Goiás. Hospital das Clínicas. Goiânia. BR
  • Castro, A. M; Universidade Federal de Goiás. Hospital das Clínicas. Goiânia. BR
  • Gomes, M. B. F; Universidade Federal de Goiás. Hospital das Clínicas. Goiânia. BR
  • Amaral, W. N; Universidade Federal de Goiás. Hospital das Clínicas. Goiânia. BR
  • Avelino, M. M; Universidade Federal de Goiás. Hospital das Clínicas. Goiânia. BR
Mem. Inst. Oswaldo Cruz ; 104(3): 434-440, May 2009. tab
Artigo em Inglês | LILACS | ID: lil-517007
Biblioteca responsável: BR1.1
ABSTRACT
A study was carried out to evaluate the presence of serological markers for the immunodiagnosis of the vertical transmission of toxoplasmosis. We tested the sensitivity, specificity and predictive values (positive and negative) of different serological methods for the early diagnosis of congenital toxoplasmosis. In a prospective longitudinal study, 50 infants with suspected congenital toxoplasmosis were followed up in the ambulatory care centre of Congenital Infections at University Hospital in Goiânia, Goiás, Brazil, from 1 January 2004-30 September 2005. Microparticle Enzyme Immunoassay (MEIA), Enzyme-Linked Fluorescent Assay (ELFA) and Immune-Fluorescent Antibody Technique (IFAT) were used to detect specific IgM anti-Toxoplasma gondii antibodies and a capture ELISA was used to detect specific IgA antibodies. The results showed that 28/50 infants were infected. During the neonatal period, IgM was detected in 39.3 percent (11/28) of those infected infants and IgA was detected in 21.4 percent (6/28). The sensitivity, specificity and predictive values (positive and negative) of each assay were, respectively MEIA and ELFA 60.9 percent, 100 percent, 100 percent, 55.0 percent; IFAT 59.6 percent, 91.7 percent, 93.3 percent, 53.7 percent; IgA capture ELISA 57.1 percent, 100 percent, 100 percent, 51.2 percent. The presence of specific IgM and IgA antibodies during the neonatal period was not frequent, although it was correlated with the most severe cases of congenital transmission. The results indicate that the absence of congenital disease markers (IgM and IgA) in newborns, even after confirming the absence with several techniques, does not constitute an exclusion criterion for toxoplasmosis.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: Doenças Negligenciadas Problema de saúde: Doenças Negligenciadas / Zoonoses Base de dados: LILACS Assunto principal: Imunoglobulina A / Imunoglobulina M / Imunoensaio / Anticorpos Antiprotozoários / Toxoplasmose Congênita Tipo de estudo: Estudo diagnóstico / Estudo de avaliação / Estudo observacional / Estudo prognóstico / Fatores de risco / Estudo de rastreamento Limite: Animais / Feminino / Humanos Idioma: Inglês Revista: Mem. Inst. Oswaldo Cruz Assunto da revista: Medicina Tropical / Parasitologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Goiás/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Contexto em Saúde: Doenças Negligenciadas Problema de saúde: Doenças Negligenciadas / Zoonoses Base de dados: LILACS Assunto principal: Imunoglobulina A / Imunoglobulina M / Imunoensaio / Anticorpos Antiprotozoários / Toxoplasmose Congênita Tipo de estudo: Estudo diagnóstico / Estudo de avaliação / Estudo observacional / Estudo prognóstico / Fatores de risco / Estudo de rastreamento Limite: Animais / Feminino / Humanos Idioma: Inglês Revista: Mem. Inst. Oswaldo Cruz Assunto da revista: Medicina Tropical / Parasitologia Ano de publicação: 2009 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Goiás/BR
...