Relación entre ubicación ecográfica transvaginal del dispositivo intra-uterino y complicaciones asociadas: profamilia, Medellín 1994-1995 / Relation between transvaginal ultrasonographic location of the intrauterine device (IUD) and the presence of complications associated with this method of contraception
CES med
; 10(2)jul.-dic. 1996. tab, graf
Article
em Es
| LILACS
| ID: lil-541374
Biblioteca responsável:
CO83.1
RESUMEN
Se determinó si la localización ecográfica transvaginal del dispositivo intrauterino (DIU), tenia relación con la presencia de complicaciones, asociadas a éste método de planificación familiar. Se estudiaron ciento cincuenta y una (151) pacientes por espacio de un año. Encontrándose 41 complicaciones (27.2 por ciento) entre las usuarias, sin diferencias estadísticamente significativas entre la ubicación del DIU y la persona que lo coloca (p= 0.5), como tampoco entre la localización y el tipo de complicación (p=0.7). La tasa de continuidad del método anticonceptivo fue del 79.8 por ciento a un año. Se presentaron cuatro embarazos (2.6 por ciento) entre las usuarias, todos ellos en pacientes en las cuales su dispositivo intrauterino se encontraba adecuadamente insertado (0-14 milímetros del fondo de la cavidad endometrial). La valoración ecográfica transvaginal del DIU, no supera a otras medidas clínicas tradicionales de la valoración del dispositivo, pero sirve como método de ayuda al clínico en los casos en los cuales la inserción del DIU ha sido difícil y no se logra la ubicación y la identificación temprana de complicaciones por los métodos tradicionales...
ABSTRACT
It was decided if the transvaginal ultrasonograpie location of the intrauterine device (IUD) had any relation to presence of complications associated with this method of contraception. One hundred fifty one (151) patients were studied durin a year. We found 41 complications (27.2%) among the patiensts without significant statistical differences betwen the location of iud and the person who inserted it (p=0.5), and neither between the location and the kind of complication. (P=0.7). The rate of continuty of the contraceptive method was 79.8% up to a year.There, were four pregnancies (2.6%) among the users of the iud, all of them in patients in which their intrauterine device was well inserted (0-14 mm from the bottom of the endometrial cavity).The transvaginal ultrasonographic valuation of the IUD, is not better than other traditional clinical methods of the valuation of the device, but it can be of the help to the doctor in cases where the insertion of the IUD has been difficult and an early location and identification of complications is not achived through conventional methods.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Gravidez não Desejada
/
Ultrassonografia
/
Dispositivos Anticoncepcionais Femininos
/
Dispositivos Intrauterinos
Tipo de estudo:
Diagnostic_studies
/
Risk_factors_studies
Limite:
Pregnancy
Idioma:
Es
Revista:
CES med
Assunto da revista:
MEDICINA
Ano de publicação:
1996
Tipo de documento:
Article
País de afiliação:
Colômbia
País de publicação:
Colômbia