Acurácia dos achados mamográficos do câncer de mama: correlação da classificação BI-RADS e achados histológicos / Accuracy of mammographic findings in breast cancer: correlation between BI-RADS classification and histological findings
Radiol. bras
; Radiol. bras;43(2): 91-96, mar.-abr. 2010. tab
Article
em En, Pt
| LILACS
| ID: lil-551815
Biblioteca responsável:
BR734.1
RESUMO
OBJETIVO:
A proposta deste estudo foi avaliar a acurácia da classificação BI-RADS® na mamografia. Os pontos secundários foram descrever a frequência de apresentação dos diferentes achados mamográficos e avaliar a concordância entre observadores.MATERIAIS E MÉTODOS:
Os exames de 115 pacientes, encaminhados para core biopsy, foram reavaliados independentemente por dois médicos especialistas, cegados, utilizando a recomendação do BI-RADS. Posteriormente, os exames foram comparados com a histologia. A acurácia da classificação BI-RADS na mamografia foi avaliada. A concordância entre os médicos foi calculada pela estatística kappa (κ) de Cohen e as diferenças nos grupos de comparação foram analisadas com teste qui-quadrado.RESULTADOS:
Esta pesquisa demonstrou que a acurácia mamográfica oscilou de 75 por cento a 62 por cento na diferenciação entre lesões benignas de malignas com o uso do BI-RADS. Houve importante concordância na descrição das margens dos nódulos (κ= 0,66). Baixa concordância foi identificada na descrição dos contornos (formas) dos nódulos (κ= 0,40) e na descrição das calcificações, tanto em relação à sua distribuição (κ= 0,24) como também em relação à morfologia (κ= 0,36).CONCLUSÃO:
O presente estudo demonstrou que o método é acurado na diferenciação de lesões benignas de malignas. A concordância foi fraca na análise das calcificações quanto a morfologia e distribuição, no entanto, identificou-se elevação progressiva dos valores preditivos positivos nas subcategorias 4.ABSTRACT
OBJECTIVE:
The present study was aimed at evaluating the BI-RADS® classification accuracy in mammography. Additionally, the frequency of different findings was described and the interobserver agreement was evaluated. MATERIALS ANDMETHODS:
Mammographic images of 115 patients were independently and blindly reviewed by two specialists in compliance with BI-RADS recommendations, and later compared with histological data. The BI-RADS accuracy in mammography was evaluated. The interobserver agreement was analyzed with the Cohen's kappa (κ) test, and the differences between groups were evaluated with the chi-squared test.RESULTS:
The present study demonstrated that the mammographic accuracy ranged from 75 percent to 62 percent in the differentiation between benign and malignant lesions with the utilization of the BI-RADS classification. Statistically significant interobserver agreement was observed in the description of masses margins (κ= 0.66). A low agreement rate was identified in the description of masses borders (shape) (κ= 0.40) and calcifications, both in relation to their distribution (κ= 0.24) and morphology (κ= 0.36).CONCLUSION:
The present study demonstrated the BI-RADS accuracy in the differentiation between benign and malignant lesions. The interobserver agreement was poor in the analysis of calcifications morphology and distribution, but a progressive increase in the positive predictive values was observed in the subcategory 4.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Neoplasias da Mama
/
Calcinose
/
Carcinoma
/
Mamografia
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
Limite:
Adult
/
Female
/
Humans
/
Male
Idioma:
En
/
Pt
Revista:
Radiol. bras
Assunto da revista:
DIAGNOSTICO POR IMAGEM
/
RADIOLOGIA
Ano de publicação:
2010
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil