Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios / Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs
Pesqui. vet. bras
; Pesqui. vet. bras;30(7): 586-592, July 2010. ilus, tab
Article
em Pt
| LILACS
| ID: lil-557305
Biblioteca responsável:
BR68.1
RESUMO
Avaliaram-se com Doppler pulsátil os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), de 30 cães considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica. Obtiveram-se os seguintes resultados para os referidos parâmetros V.max. AO= 1,22± 19,38m/s; V. Me. AO= 0,72± 0,08m/s; VTI AO= 0,14± 0,02m; TA AO= 38,80± 11,29ms; TE AO= 197,90± 24,77ms; V. Max. Pul= 0,95± 0,18m/s; V. Me. Pul= 0,63± 0,10m/s; VTI Pul= 0,13± 0,02m; TA Pul= 70,97± 18,87ms; TE Pul= 203,70± 28,98ms. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros apresentaram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul); outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VTI Pul, TE Pul,) e não se observou influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul.
ABSTRACT
This study evaluated aortic (AO) and pulmonary (Pul)valves flow with pulsed-wave Doppler by qualitative (presence of valvar insufficiency and characteristic of flow profile) and quantitative analysis, and the following echocardiographic parameters were obtained peak (PV) and mean (MV) velocities, velocity-time integral (VTI), acceleration (AT) and ejection (ET) time. Thirty dogs were studied, and to be considered normal, physical, laboratory, electrocardiographic, echocardiographic (uni and bidimensional mode) exams, thoracic radiography, and measurement of the blood pressure were accomplished, and the following echocardiographic parameters were obtained AO PV= 1.22± 19.38m/s; AO MV= 0.72± 0.08m/s; AO VTI= 0.14± 0.02m; AO AT= 38.80± 11.29ms; AO ET= 197.90± 24.77ms; Pul PV= 0.95± 0.18m/s; Pul MV= 0.63± 0.10m/s; Pul VTI= 0.13± 0.02m; Pul AT= 70.97± 18.87ms; Pul ET= 203.70± 28.98ms. Heart rate presented negative correlation with AO VTI, AO ET, Pul VTI, Pul AT, Pul ET, and the variable weight had positive correlation with AO VTI, AO AT, AO ET, Pul VTI, Pul ET, differently from the gender, that had no influence on the evaluated parameters. The comparison of aortic and pulmonary valves flow demonstrated AO PV and AO MV higher than Pul PV and Pul MV, respectively, AO VTI higher than Pul VTI, and Pul AT higher than AO AT.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Ecocardiografia Doppler de Pulso
/
Técnicas de Diagnóstico Cardiovascular
Tipo de estudo:
Qualitative_research
Limite:
Animals
Idioma:
Pt
Revista:
Pesqui. vet. bras
Assunto da revista:
MEDICINA VETERINARIA
Ano de publicação:
2010
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil