Avaliação sistematizada da dificuldade de exposição das pregas vocais na microcirurgia da laringe / Difficulty systematized evaluation of vocal folds exposure in microsurgery of the larynx
Ballin, Annelyse Cristine; Macedo Filho, Evaldo Dacheux de; Sela, Gustavo B; Catani, Guilherme S; Ido Filho, Jorge Massaaki; Ballin, Carlos Henrique; Mocellin, Marcos.
Afiliação
  • Ballin, Annelyse Cristine; Universidade Federal do Paraná. Hospital das Clínicas. Serviço de Otorrinolaringologia. Curitiba. BR
  • Macedo Filho, Evaldo Dacheux de; Universidade Federal do Paraná. Hospital das Clínicas. Setor de Laringologia da Disciplina de Otorrinolaringologia. Curitiba. BR
  • Sela, Gustavo B; Universidade Federal do Paraná. Curitiba. BR
  • Catani, Guilherme S; Universidade Federal do Paraná. Hospital das Clínicas. Setor de Laringologia. Curitiba. BR
  • Ido Filho, Jorge Massaaki; Universidade Federal do Paraná. Hospital das Clínicas. Setor de Laringologia. Curitiba. BR
  • Ballin, Carlos Henrique; Universidade Federal do Paraná. Curitiba. BR
  • Mocellin, Marcos; Universidade Federal do Paraná. Hospital das Clínicas. Serviço de Otorrinolaringologia. Curitiba. BR
Arq. int. otorrinolaringol. (Impr.) ; 14(3)jul.-set. 2010. ilus, tab
Artigo em Português, Inglês | LILACS | ID: lil-558344
Biblioteca responsável: BR66.1
RESUMO

Introdução:

Diversos estudos abordam fatores pré-operatórios que predizem dificuldade de intubação endotraqueal, graduada pelos anestesistas pela escala de Cormack-Lehane. Estes parâmetros foram pouco avaliados para a dificuldade de locação do laringoscópio nas microcirurgias da laringe. Não há uma escala padrão de dificuldade direcionada aos cirurgiões de laringe.

Objetivo:

Criar uma escala padrão de dificuldade de locação do laringoscópio durante microcirurgia da laringe, com foco na exposição das pregas vocais (PPVV); avaliar quais parâmetros clínicos predizem dificuldade de exposição das PPVV; verificar a melhora da exposição laríngea com o suspensor do laringoscópio.

Método:

Estudo prospectivo, randomizado, de 57 pacientes submetidos à microcirurgia de laringe. No pré-operatório foram avaliados 3 dados epidemiológicos, 2 de anamnese e 13 de exame físico. No intra-operatório o anestesista avaliava o escore de Cormack-Lehane e o cirurgião avaliava conforme a escala proposta, antes e após a colocação do suspensor. Resultados e

Conclusão:

Vários parâmetros apresentaram sensibilidade, especificidade, valor preditivo positivo altos para exposição inadequada da laringe. Porém, apenas distância hiomentual <6,05cm (p=0,003) e classe 2 de Cormack-Lehane (p=0,04) com significância estatística e alta sensibilidade, 100% e 81% respectivamente. O uso do suspensor do laringoscópio melhorou a exposição laríngea de forma significativa (p=0,04). A escala proposta padroniza a vizualização e gradua a dificuldade de exposição das PPVV, facilitando comparações entre estudos e comunicação entre otorrinolaringologistas.
ABSTRACT

Introduction:

Several studies addressing preoperative factors that predict difficulty of endotracheal intubation graduated by anesthesiologists, for the scale of the Cormack-Lehane. These parameters were evaluated for the difficulty of location of the laryngoscope in microsurgery of the larynx. There is not a standard scale of difficulty targeted to surgeons of the larynx.

Objective:

Create a standard scale of difficulty leasing the laryngoscope during microsurgery of the larynx, with a focus on exposure of the vocal folds (vocal cords) to evaluate which clinical parameters predict difficulty of exposure of their vocal folds and verify the improvement of laryngeal exposure with the hanger of the laryngoscope.

Method:

A prospective randomized study, 57 patients undergoing laryngeal microsurgery. The preoperative parameters were evaluated three epidemiological data, two of history and 13 physical examination. Intraoperatively the anesthesiologist evaluated the Cormack-Lehane score and the surgeon evaluated according to the proposed scale, before and after placement of the hanger. Results and

Conclusion:

Several parameters showed sensitivity, specificity, positive predictive value for high inadequate exposure of the larynx. But only distance hiomentual <6.05 cm (p = 0.003) and 2 classes of Cormack-Lehane (p = 0.04) with statistical significance and high sensitivity of 100% and 81% respectively. The use of the hanger of laryngoscope laryngeal exposure improved significantly (p = 0.04). The proposed scale standardizes the visualization and grades the difficulty of exposure of their vocal folds, facilitating comparisons between studies and communication between otolaryngologists.
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Procedimentos Cirúrgicos Otorrinolaringológicos / Prega Vocal / Laringectomia / Microcirurgia Tipo de estudo: Ensaio clínico controlado / Estudo observacional / Estudo prognóstico Idioma: Inglês / Português Revista: Arq. int. otorrinolaringol. (Impr.) Assunto da revista: Otorrinolaringologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Paraná/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Procedimentos Cirúrgicos Otorrinolaringológicos / Prega Vocal / Laringectomia / Microcirurgia Tipo de estudo: Ensaio clínico controlado / Estudo observacional / Estudo prognóstico Idioma: Inglês / Português Revista: Arq. int. otorrinolaringol. (Impr.) Assunto da revista: Otorrinolaringologia Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Paraná/BR
...