Your browser doesn't support javascript.
loading
Efecto del ruido sobre la presión arterial en trabajadores de una empresa petrolera venezolana / Effect of noise on blood pressure in workers of a venezuelan oil company
Fernández-D´Pool, Janice; Butrón, Jorge; Colina-Chourio, José.
Afiliação
  • Fernández-D´Pool, Janice; Universidad del Zulia. Facultad de Medicina. Instituto de Medicina del Trabajo e Higiene Industrial. Maracaibo. VE
  • Butrón, Jorge; Universidad del Zulia. Facultad de Medicina. Instituto de Medicina del Trabajo e Higiene Industrial. Maracaibo. VE
  • Colina-Chourio, José; Universidad del Zulia. Facultad de Medicina. Cátedras de Fisiología y Farmacología. Maracaibo. VE
Invest. clín ; 51(3): 301-314, Sept. 2010. tab
Artigo em Espanhol | LILACS | ID: lil-574456
Biblioteca responsável: VE1.1
RESUMEN
El ruido ocupacional se relaciona con efectos cardiovasculares, no obstante epidemiológicamente no se ha dado una explicación clara. Para determinar el desarrollo de hipertensión arterial (HTA) en trabajadores expuestos a intensidad de ruido superior a 85 dB(A) y relacionarla con el área de trabajo, antigüedad laboral y el uso de protección auditiva, se realizó un estudio de casos y controles en una industria petrolera venezolana. Se incluyeron 50 trabajadores masculinos en cada grupo de acuerdo a los criterios de inclusión y exclusión, la información se obtuvo de la historia clínica ocupacional para evaluar los elementos en estudio y los niveles de ruido ambiental fueron obtenidos mediante metodología recomendada en la Norma Venezolana COVENIN 1565-95. La edad media en los casos y controles fue de 39 ± 0,06 y de 44 ± 0,44 años respectivamente, la antigüedad laboral fue similar en ambos grupos; 22 por ciento y 48 por ciento de casos y controles respectivamente tuvieron antecedentes familiares de HTA (p<0,05), siendo elevada su prevalencia en ambos grupos, al igual que el sobrepeso. En 92 por ciento de los casos y 80 por ciento de los controles se encontraron cifras normales de glucemia (p<0,01); 68 por ciento y 84 por ciento de casos y controles, respectivamente, presentaron alteraciones de las cifras de lípidos (p<0,05). La medición del ruido ambiental registró niveles que excedieron los 85 dB(A), 87,78 ± 1,10 dB(A) (p<0,01). El 94 por ciento de los casos utilizaban protección auditiva, de ellos el 60 por ciento (27/45) presentaron HTA, mientras que de los que no lo utilizaban 80 por ciento (4/5) la presentó, sin observar relación significante entre la pérdida auditiva inducida por ruido ocupacional e HTA, intensidad de exposición y la antigüedad laboral con la prevalencia de HTA. No se pudo concluir que el ruido ocupacional fuese un factor determinante en el desarrollo de HTA en trabajadores expuestos.
ABSTRACT
Occupational noise has been related to cardiovascular events, although epidemiologically, there is not a clear explanation. To determine the development of arterial hypertension in workers exposed to a noise level higher than 85 dB (A) and to relate it with the working place, labor antiquity and the use of auditive protection, a case-control study was done in a Venezuelan oil company. Fifty working men, that fulfilled the inclusion and exclusion criteria, were included in each group. The information was obtained from the occupational clinical history, based on international guidelines, to evaluate the parameters of the study, The intensity of environmental noise was obtained according to recommended Venezuelan “Norma COVENIN 1565-95". The mean age of cases and controls were 39 ± 0.06 and 44 ± 0.44 years old respectively; the labor seniority was similar in both groups; 22 an 48 percent of cases and controls respectively had a family history of arterial hypertension (p<0.05), without a high significant prevalence in both groups. In both groups we observed overweight. In 92 percent of cases and 80 percent of controls there were normal levels of glucose (p<0.01); 68 and 84 percent of cases and controls, respectively, presented alterations of the lipid levels (p<0.05). The measurements of environmental noise registered levels that exceeded 85 dB (A), being the mean 87.78 ± 1.10 dB (A); 94 percent of the cases used hearing protective equipment and 60 percent of them presented arterial hypertension and 80 percent of those that did not used it, showed arterial hypertension. There was not a significant relationship among the auditive loss induced by occupational noise, its intensity and labor seniority with the prevalence of arterial hypertension. We cannot conlude that occupational noise is a decisive factor in the development of arterial hypertension in noise exposed workers.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Pressão Sanguínea / Saúde Ocupacional / Ruído Ocupacional Tipo de estudo: Guia de prática clínica / Avaliação de tecnologias de saúde / Estudo observacional / Fatores de risco Aspecto: Determinantes sociais da saúde Limite: Adulto / Humanos / Masculino País/Região como assunto: América do Sul / Venezuela Idioma: Espanhol Revista: Invest. clín Assunto da revista: Biologia / Medicina / Relatos de Casos Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Venezuela Instituição/País de afiliação: Universidad del Zulia/VE

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Pressão Sanguínea / Saúde Ocupacional / Ruído Ocupacional Tipo de estudo: Guia de prática clínica / Avaliação de tecnologias de saúde / Estudo observacional / Fatores de risco Aspecto: Determinantes sociais da saúde Limite: Adulto / Humanos / Masculino País/Região como assunto: América do Sul / Venezuela Idioma: Espanhol Revista: Invest. clín Assunto da revista: Biologia / Medicina / Relatos de Casos Ano de publicação: 2010 Tipo de documento: Artigo País de afiliação: Venezuela Instituição/País de afiliação: Universidad del Zulia/VE
...