Confiabilidade e aplicabilidade de dois métodos de avaliação da amplitude de movimento de dorsiflexão do tornozelo / Reliability and applicability of two methods for evaluating the range of motion for ankle dorsiflexion
Conscientiae saúde (Impr.)
; 10(1)mar. 2011.
Artigo
em Português
| LILACS
| ID: lil-583322
Biblioteca responsável:
BR1.1
RESUMO
Introdução:
A limitação da amplitude de movimento de dorsiflexão é o parâmetro mais utilizado na avaliação e evolução da abordagem fisioterapêutica.Objetivos:
Avaliar a confiabilidade e aplicabilidade da goniometria e do teste Weight-Bearing para a mensuração de dorsiflexão do tornozelo.Método:
Participaram 25 voluntários, do sexo masculino, com idade média de 38,81 (± 6,26), distribuídos em dois grupos G1 (n=13 Não-atleta) e G2 (n=12 Atletas). A medida da dorsiflexão do tornozelo foi realizada com goniômetro universal adaptado com haste metálica de 45 cm e por meio do teste Weigth-Bearing. Os dois métodos foram aplicados nos participantes por três examinadores, cada um efetuando a mensuração seis vezes. Com o ICC, verificou-se a confiabilidade dos testes.Resultados:
Obtiveram-se ICC de 0,98 na goniometria, para o G1, e 0,97, para o G2. Já para o Weight-Bearing, obteve-se ICC de 0,98 para o G1 e o mesmo para o G2. Todas essas medidas foram consideradas muito elevadas.Conclusão:
Ambos os métodos são de alta confiabilidade para aplicação clínica nessas condições experimentais.ABSTRACT
Introduction:
The limitation of the dorsiflexion movement range is the most used parameter in evaluation and evolution of physiotherapeutic approach.Objective:
To evaluate the inter-tester reliability and the applicability of goniometry and Weight-Bearing test for measuring the ankle dorsiflexion.Method:
Twenty five volunteers, male sex, average aged 38.81 (+6.26), were included in the study and distributed in G1 (13 non-athletes) and G2 (12 athletes). The measurement of the ankle dorsiflexion was made by using a universal goniometer, which was adapted with a 45 cm metal rod, and also by using the Weight-Bearing test. The two methods were applied in all the participants, by three clinical examiners, each of whom made the measurement six times. The ICC was used to verify the reliability of the tests.Results:
In goniometry, the ICC was 0.98 for G1 and 0.97 for G2. When it comes to Weight-Bearing, the ICC was 0.98 for G1 and the same for G2. All these measures were considered high values.Conclusion:
As a conclusion, it may be said that both methods are of great reliability for clinical application in these experimental conditions.
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Base de dados:
LILACS
Assunto principal:
Artrometria Articular
/
Treinamento Resistido
Limite:
Adulto
/
Humanos
/
Masculino
Idioma:
Português
Revista:
Conscientiae saúde (Impr.)
Assunto da revista:
Medicina
/
MEDICINA FISICA E REABILITACAO
Ano de publicação:
2011
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
UCDB/BR
/
Uniderp/BR
/
Unisalesiano/BR