Your browser doesn't support javascript.
loading
Avaliação da força liberada por fios ortodônticos de níquel-titânio associados a bráquetes autoligante / Avalied of the deactivated force by termoatived nickel-titanium wire associated with self-ligation brackets
Zucch, Temístocles Uriarte; Nóbrega, Celestino; Benetti, Jairo J; Gick, Márcio Rivero; Jakob, Sérgio Ricardo; Arsati, Franco.
Afiliação
  • Zucch, Temístocles Uriarte; Faculdade CIODONTO. Sarandi. BR
  • Nóbrega, Celestino; Faculdade CIODONTO. BR
  • Benetti, Jairo J; Faculdade CIODONTO. BR
  • Gick, Márcio Rivero; Faculdade CIODONTO. BR
  • Jakob, Sérgio Ricardo; Faculdade CIODONTO. BR
  • Arsati, Franco; Faculdade de Odontologia São Leopoldo Mandic. BR
Ortho Sci., Orthod. sci. pract ; 3(13): 407-413, 2011. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-589658
Biblioteca responsável: BR243.1
RESUMO
O presente estudo teve como objetivo avaliar a força liberada por fios ortodônticos de Níquel-Titânio (Niti) termoativados de secção redonda 0,016¨, quando submetidos a deflexões de 4, 3,5, 3, 2,5, 2, 1,5, 1, 0,5 e 0 mm. Foram selecionadas seis diferentes marcas comerciais de fios (GAC®, Ormco®, Morelli®, Aditek®, US Company® e 3M®, para cada marca comercial foram realizados dez ensaios. Para a realização dos ensaios foi desenvolvido um protótipo, com braquetes autoligantes GAC®, onde o fio ortodôntico foi adaptado. Esse sistema foi colocado em uma máquina de ensaios (EMIC DL 2000), calibrada em 5Kgf e com velocidade de 1mm/min. Todos os ensaios foram realizados em temperatura constante. Por meio de um software os valores de desativação (g) foram registrados e demonstrados através de gráficos de força em função da deflexão, finalizando 60 ensaios. As variáveis foram submetidas á análise de variância e ao teste de Turkey para determinar as diferenças entre as marcas comerciais testadas adotando um nível de significância de 5%. Os resultados demonstraram que na desativação de 4mm para 3mm todos os fios apresentaram redução acentuada de força, característica comum dos fios termoativados e que todas as marcas comerciais estudadas apresentaram liberação de força relativamente constante.
ABSTRACT
The purpose of this study was to evaluate the deactivation force of Nickel-Titanium termoatived wire with round diameter of 0.016¨, when put into 4; 3.5; 3; 2.5; 2; 1.5, 1, 0.5 and 0 mm deflections. For this purpose was used six different wire trade make ( Gac® ,Ormco® ,Morelli® ,Aditek®Us Company®and 3M®)for each trade make was done ten rehearsals. For the test a prototype was developed, with self-ligation brackets GAC®, where orthodontic wire was adapted. The system was adapted in a Universal rehearses machine (EMIC DL 2000) adjusted in 5kgf and with speed of 1mm/min. All the rehearsals were done in constant temperature. Through software the activation values (g) were registered and showed by the power graphics in relation to the deflection, totalizing 60 rehearsals. The variables were subjected to the analysis of variance and test of Turkey to determine the differences between trademarks tested by adopting a significance level of 5%. The result showed that the deactivation of 4mm to 3mm all wires showed severe redution in force, a common characteristic of thermal activated wires and all trademarks studied had relatively constant release of force.
Assuntos

Buscar no Google
Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Fios Ortodônticos / Técnicas de Movimentação Dentária Tipo de estudo: Fatores de risco Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Assunto da revista: Odontologia / Ortodontia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade CIODONTO/BR / Faculdade de Odontologia São Leopoldo Mandic/BR
Buscar no Google
Coleções: Bases de dados internacionais Base de dados: BBO - Odontologia / LILACS Assunto principal: Fios Ortodônticos / Técnicas de Movimentação Dentária Tipo de estudo: Fatores de risco Idioma: Português Revista: Ortho Sci., Orthod. sci. pract Assunto da revista: Odontologia / Ortodontia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Faculdade CIODONTO/BR / Faculdade de Odontologia São Leopoldo Mandic/BR
...