Your browser doesn't support javascript.
loading
A Reassessment of the in vitro total protein content determination (TPC) with SIRC and 3T3 cells for the evaluation of the ocular irritation potential of shampoos: comparison with the in vivo Draize rabbit test
Costa, Rodrigo Netto; Abreu, Clarice Lima do Canto; Presgrave, Rosaura Farias; Alves, Eloisa Nunes; Presgrave, Octavio Augusto França; Delgado, Isabella Fernandes.
Afiliação
  • Costa, Rodrigo Netto; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Imunologia. Rio de Janeiro. BR
  • Abreu, Clarice Lima do Canto; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Imunologia. Rio de Janeiro. BR
  • Presgrave, Rosaura Farias; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Farmacologia e Toxicologia. Rio de Janeiro. BR
  • Alves, Eloisa Nunes; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Farmacologia e Toxicologia. Rio de Janeiro. BR
  • Presgrave, Octavio Augusto França; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Farmacologia e Toxicologia. Rio de Janeiro. BR
  • Delgado, Isabella Fernandes; Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Departamento de Imunologia. Rio de Janeiro. BR
Braz. arch. biol. technol ; 54(6): 1135-1146, Nov.-Dec. 2011. tab
Artigo em Inglês | LILACS | ID: lil-608434
Biblioteca responsável: BR1.1
ABSTRACT
The aim of this work was to determine the correlation between results obtained from the Draize test and from the Total Protein Content Determination (TPC) to assess the ocular irritancy potential of 20 shampoos. For TPC, two established cell lines (SIRC and 3T3) were used. The concentration that induced 50 percent inhibition relative to controls (IC50) was calculated for each product. Among shampoos tested with SIRC, only one had a false positive result. However, for the 3T3, three false-negative results were found. Pearson coefficient related to the in vivo value of maximum average score (MAS) was -0.58 (p=0.007) with SIRC and -0.73 (p=0.007) with 3T3. These results showed that the TPC assay was capable to predict the ocular irritant potential of shampoos, and therefore was a promissory tool to be used as a preliminary assay for the detection of irritant products and to be part of a battery of screening tests to minimize the animal use in the Draize Test.


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Tipo de estudo: Estudo prognóstico Idioma: Inglês Revista: Braz. arch. biol. technol Assunto da revista: Biologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Fundação Oswaldo Cruz/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Tipo de estudo: Estudo prognóstico Idioma: Inglês Revista: Braz. arch. biol. technol Assunto da revista: Biologia Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Fundação Oswaldo Cruz/BR
...