Your browser doesn't support javascript.
loading
Avaliação da confiabilidade e usabilidade de três diferentes programas computacionais para a análise fotogramétrica do ângulo de flexão de quadril / Reliability and usability assessment of three different softwares for photogrammetric analysis of hip flexion angle
Guariglia, Débora Alves; Pereira, Ligia Maxwell; Pereira, Hugo Maxwell; Cardoso, Jefferson Rosa.
Afiliação
  • Guariglia, Débora Alves; s.af
  • Pereira, Ligia Maxwell; s.af
  • Pereira, Hugo Maxwell; s.af
  • Cardoso, Jefferson Rosa; Universidade Estadual de Londrina. Departamento de Fisioterapia. Londrina. BR
Fisioter. pesqui ; 18(3): 247-251, jul.-set. 2011. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-613696
Biblioteca responsável: BR66.1
RESUMO
A análise fotogramétrica pode ser feita por meio de diferentes programas computacionais. Assim, o objetivo do presente estudo foi avaliar a confiabilidade e usabilidade de três diferentes programas em uma análise fotogramétrica durante a flexão do quadril e discutir aspectos qualitativos e quantitativos de cada um deles. Participaram do estudo 26 voluntários do gênero masculino, com idade entre 19 e 30 anos (x=25,4 anos, DP=2,5) que realizaram o teste do sentar e alcançar por meio do banco de Wells adaptado. Marcadores cutâneos foram posicionados nos processos ósseos trocânter maior do fêmur e espinha ilíaca anterossuperior. A aquisição da imagem foi realizada no limite máximo da execução do teste. Todos os programas apresentaram uma alta confiabilidade entre as medidas, além disso, foram apresentadas vantagens e desvantagens específicas na adoção de cada um deles. O programa SAPO foi considerado com maiores vantagens para utilização na prática profissional, no entanto, para realização de análises em pesquisas científicas todos os programas apresentam pontos que devem ser considerados antes da sua adoção.
ABSTRACT
The photogrammetric analysis can be done by using different softwares. Thus, the purpose of this study was to assess the reliability and the usability of three different softwares during the hip flexion photogrammetric analysis and to discuss the qualitative and quantitative aspects of each one. Twenty-six volunteers participated in this study with age between 19 and 30 years old (x=25.4 years, SD=2.5) who underwent the sit-to-reach test through adapted Wells´ bench. Reflective skin markers were positioned in the anterior superior iliac spine and greater trochanter. The image acquisition was collected in the maximum limit of test execution. All softwares showed a high reliability between measures, besides it was presented specifics advantages and disadvantages during adoption one of them. SAPO´s software was considered with major points for professional practice, although taking the analysis for scientific research all softwares demonstrated characteristics that must be taken into consideration before adopting them.
Assuntos
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Fenômenos Biomecânicos / Reprodutibilidade dos Testes / Amplitude de Movimento Articular / Articulação do Quadril Tipo de estudo: Estudo de avaliação / Pesquisa qualitativa Limite: Adolescente / Adulto / Humanos / Masculino Idioma: Português Revista: Fisioter. pesqui Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Londrina/BR
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Fenômenos Biomecânicos / Reprodutibilidade dos Testes / Amplitude de Movimento Articular / Articulação do Quadril Tipo de estudo: Estudo de avaliação / Pesquisa qualitativa Limite: Adolescente / Adulto / Humanos / Masculino Idioma: Português Revista: Fisioter. pesqui Assunto da revista: MEDICINA FISICA E REABILITACAO Ano de publicação: 2011 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Londrina/BR
...