Your browser doesn't support javascript.
loading
Potencial Evocado Auditivo de Estado Estável com estímulo de ruído branco modulado em amplitude em triagem auditiva neonatal / Neonatal hearing screening using auditory steady state responses with amplitude modulated white noise stimuli
Pinto, Danielle Gomes; Griz, Silvana Maria Sobral; Lins, Otávio Gomes.
Afiliação
  • Pinto, Danielle Gomes; Universidade Federal de Pernambuco. Departamento de Fonoaudiologia. Recife. BR
  • Griz, Silvana Maria Sobral; Universidade Federal de Pernambuco. Departamento de Fonoaudiologia. Recife. BR
  • Lins, Otávio Gomes; Universidade Federal de Pernambuco. Departamento de Medicina. Recife. BR
Rev. CEFAC ; 14(3): 383-389, mayo-jun. 2012. tab
Artigo em Português | LILACS | ID: lil-640883
Biblioteca responsável: BR1.1
RESUMO

OBJETIVO:

verificar a utilização do estímulo ruído branco, modulado em amplitude, no exame de Potencial Evocado Auditivo de Estado Estável (PEAEE).

MÉTODO:

foram avaliados 30 neonatos e lactentes, na Maternidade do Hospital das Clínicas da UFPE, que realizaram os exames de Emissões Otoacústicas Transientes (EOAT) e PEAEE, com ruído branco de amplitude modulada.

RESULTADOS:

para o exame de PEAEE, sugere-se que a intensidade ideal para o ponto de corte seja 50 dB NPS, para os casos com passa na triagem auditiva, com o exame de EOAT.

CONCLUSÃO:

o exame de PEAEE, realizado com ruído branco, modulado em amplitude, parece ser promissor como ferramenta de triagem auditiva. Entretanto, estudos são necessários para observar a relação entre os limiares das respostas auditivas de estado estável utilizando-se tons puros e ruído branco, a fim de melhor elucidar e definir parâmetros e protocolos de sua utilização.
ABSTRACT

PURPOSE:

to check the use of amplitude modulated white noise as a stimulus for the auditory steady state response.

METHOD:

thirty neonates were evaluated with transient otoacoustic emissions and auditory steady state response, with amplitude modulate white noise, at the Clinical Hospital in the Federal University of Pernambuco.

RESULTS:

for the auditory steady state response, it is suggested that the cut point intensity related with normal hearing is 50 dB SPL, as it was related to the presence of transient otoacoustic emissions.

CONCLUSION:

the auditory steady state response, evoked with amplitude modulate white noise seems to be promissory as a tool for hearing screening. More studies need to be done in order to better establish the hearing threshold and to define more precise protocols for its employment.


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Tipo de estudo: Estudo diagnóstico / Guia de prática clínica / Estudo de rastreamento Idioma: Português Revista: Rev. CEFAC Assunto da revista: Terapia / Patologia da Fala e Linguagem / Terapia / Reabilita‡Æo Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Pernambuco/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Tipo de estudo: Estudo diagnóstico / Guia de prática clínica / Estudo de rastreamento Idioma: Português Revista: Rev. CEFAC Assunto da revista: Terapia / Patologia da Fala e Linguagem / Terapia / Reabilita‡Æo Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Pernambuco/BR
...