Your browser doesn't support javascript.
loading
Etiology of anemia of blood donor candidates deferred by hematologic screening
Silva, Michel Alves da; Souza, Renata Andréia Volpe de; Carlos, Aline Meneses; Soares, Sheila; Moraes-Souza, Helio; Pereira, Gilberto de Araujo.
Afiliação
  • Silva, Michel Alves da; Universidade Federal de Minas Gerais. Belo Horizonte. BR
  • Souza, Renata Andréia Volpe de; Universidade Federal do Triângulo Mineiro. Uberaba. BR
  • Carlos, Aline Meneses; Universidade Federal do Triângulo Mineiro. Uberaba. BR
  • Soares, Sheila; Universidade Federal do Triângulo Mineiro. Uberaba. BR
  • Moraes-Souza, Helio; Universidade Federal do Triângulo Mineiro. Uberaba. BR
  • Pereira, Gilberto de Araujo; Universidade Federal do Triângulo Mineiro. Uberaba. BR
Rev. bras. hematol. hemoter ; 34(5): 356-360, 2012. tab
Artigo em Inglês | LILACS | ID: lil-654977
Biblioteca responsável: BR408.1
Localização: BR408.1
ABSTRACT

OBJECTIVE:

Iron deficiency is the most common cause of anemia and one of the main factors in the clinical deferral of blood donors. This fact prompted the current study that aimed to determine the prevalence and etiology of anemia in blood donor candidates and to evaluate the hematological screening technique used for the exclusion of these donors.

METHODS:

This was a prospective study that compared two groups (Anemic and Non-anemic). Initially screening for anemia was performed by manually measuring hemoglobin (Bioclin® Kit); the results were subsequently compared with an automated screening method (Coulter T-890). The etiology was investigated by hemoglobin electrophoresis in alkaline and acid pH, Hb A2 dosage and measurement of the ferritin concentration by immunoagglutination. Differences and associations of interest were analyzed using the Yates and McNemar's Chi-square tests and the Fisher, Mann-Whitney, Wilcoxon and Kruskal-Wallis tests.

RESULTS:

The deferral rate due to anemia was 4.2%; iron deficiency was identified in 37.5% and beta thalassemia in 9.3% of the excluded candidates. There was a significant discrepancy between the two techniques used to measure hemoglobin with 38.1% of initially deferred donors presenting normal hemoglobin levels by the automated method.

CONCLUSION:

The results show a high rate of blood donors being deferred for anemia and confirm that iron deficiency is the most prevalent cause. The discrepancies found by comparing screening methods suggest that hemoglobin and hematocrit levels should be confirmed before deferring a donor due to anemia; this may increase supplies in blood banks.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Doadores de Sangue / Anemia Ferropriva / Seleção do Doador Tipo de estudo: Estudo diagnóstico / Estudo de etiologia / Estudo observacional / Estudo prognóstico / Fatores de risco / Estudo de rastreamento Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Rev. bras. hematol. hemoter Assunto da revista: Hematologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais/BR / Universidade Federal do Triângulo Mineiro/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Doadores de Sangue / Anemia Ferropriva / Seleção do Doador Tipo de estudo: Estudo diagnóstico / Estudo de etiologia / Estudo observacional / Estudo prognóstico / Fatores de risco / Estudo de rastreamento Limite: Feminino / Humanos / Masculino Idioma: Inglês Revista: Rev. bras. hematol. hemoter Assunto da revista: Hematologia Ano de publicação: 2012 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal de Minas Gerais/BR / Universidade Federal do Triângulo Mineiro/BR
...