Rice detector: proposal of a novel objective response detection technique
Farina Júnior, Paulo Danilo; Melges, Danilo Barbosa; Infantosi, Antonio Fernando Catelli; Sá, Antonio Mauricio Ferreira Leite Miranda de.
Afiliação
  • Farina Júnior, Paulo Danilo; Universidade Federal do Rio de Janeiro - UFRJ. Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia - COPPE. Rio de Janeiro. BR
  • Melges, Danilo Barbosa; Universidade Federal do Rio de Janeiro - UFRJ. Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia - COPPE. Rio de Janeiro. BR
  • Infantosi, Antonio Fernando Catelli; Universidade Federal do Rio de Janeiro - UFRJ. Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia - COPPE. Rio de Janeiro. BR
  • Sá, Antonio Mauricio Ferreira Leite Miranda de; Universidade Federal do Rio de Janeiro - UFRJ. Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia - COPPE. Rio de Janeiro. BR
Rev. bras. eng. biomed ; 29(4): 321-328, dez. 2013. graf
Artigo em Inglês | LILACS | ID: lil-697279
Biblioteca responsável: BR1.1
ABSTRACT

INTRODUCTION:

The detection of the somatosensory response (SR) is an important tool for the neurophysiological evaluation in the intra and post-operative period of some vascular and spine surgeries. Particularly, the SR identification with a maximum false positive ratio by means of Objective Response Detection (ORD) techniques could lead to a less subjective procedure. In this work a novel ORD, the Rice Detector (RD), is presented and its theoretical critical value is obtained.

METHODS:

The probability of detection (PD) of RD is assessed for different numbers of eletroencephalographic (EEG) signal epochs (M = 30, 60, 120, 240) and signal-to-noise ratios (-20 to 10 dB, in steps of 1 dB) by means of simulation. The simulated PD curves (PDc) are compared with the theoretical ones and with the PDc of the Magnitude-Squared Coherence (MSC), a well-known ORD technique. The performance of RD and MSC are also compared for real EEG data. The comparison is based on the DP for estimates calculated with M = 30, 60, 120 and 240 epochs.

RESULTS:

The results showed that the simulated PDc follow the theoretical ones and both the MSC and RD present similar performance, with slight advantage for this latter at low M-values. However, for real data, no statistical significant difference (proportion test with alpha=0.05) was found between MSC and RD.

CONCLUSION:

Both techniques presented mean detection rates varying from 70% to 90%, even for intermediate M-value (120 epochs), and can be useful for evoked response detection applications.


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Tipo de estudo: Estudo diagnóstico Idioma: Inglês Revista: Rev. bras. eng. biomed Assunto da revista: Engenharia Biomédica Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Rio de Janeiro - UFRJ/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Tipo de estudo: Estudo diagnóstico Idioma: Inglês Revista: Rev. bras. eng. biomed Assunto da revista: Engenharia Biomédica Ano de publicação: 2013 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Federal do Rio de Janeiro - UFRJ/BR
...