Impacto en el diagnóstico y tratamiento del monitoreo hemodinámico con catéter de Swan Ganz en el paciente grave inestable / Impact of hemodynamic monitoring with Swan-Ganz catheter in the diagnosis and treatment in unstable seriously ill patients
Arch. méd. Camaguey
; 18(6): 633-641, nov.-dic. 2014. tab
Article
em Es
| LILACS, CUMED
| ID: lil-728470
Biblioteca responsável:
CU1.1
RESUMEN
FUNDAMENTO el catéter de la arteria pulmonar o de Swan Ganz es un método técnico de diagnóstico y se desarrolla en los laboratorios de fisiología y hemodinámica, en el mismo se perfeccionó a punto de proporcionarle un recurso incuestionable para el control y seguimiento por el anestesiólogo en el período perioperatorio de pacientes de cirugía de alto riesgo. OBJETIVO:
evaluar la repercusión del monitoreo hemodinámico invasivo con catéter de Swan Ganz.MÉTODO:
se realizó un estudio prospectivo descriptivo en la sala de Cuidados Intensivos del Hospital Universitario Manuel Ascunce Domenech desde enero de 1992 a enero de 2014. Se estudió un universo de 500 pacientes, con edad comprendida entre 15 y 70 años y con diagnóstico de inestabilidad hemodinámica de origen cardiogénico 298 pacientes y no cardiogénico 202.RESULTADOS:
su uso motivó cambios en el diagnóstico o adición de otro en 317 pacientes 63,4 %. En relación al tratamiento se realizaron cambios o modificaciones en 450 pacientes en total, lo que significó un 90 %.CONCLUSIONES:
el uso racional y bien discutido del catéter de Swan Ganz resultó de suma utilidad para el manejo de pacientes graves con inestabilidad hemodinámica, lo que permitió una mejor interpretación de estados fisiopatológicos confusos y modalidades terapéuticas oportunas y de difícil decisión.ABSTRACT
OBJECTIVE:
to evaluate the repercussion of the invasive hemodynamic monitoring with Swan-Ganz catheter; to show the benefits and repercussions of its hemodynamic use in the diagnosis and treatment of unstable seriously ill patients in the first 72 hours of evolution.METHOD:
a prospective, descriptive study was conducted in the Intensive Care room of the Manuel Ascunce Domenech Teaching Hospital from January, 1992 to January 2014. A universe of 500 patients aged 15-70 years old was studied; 298 of them were diagnosed with hemodynamic instability of a cardiogenic origin and 202 with hemodynamic instability of a non-cardiogenic origin.RESULTS:
its use motivated changes in the diagnosis, or the addition of another diagnosis, in 317 patients 63, 4 %. Regarding the treatment, changes or modifications were made in a total of 450 patients, which represented a 90 %.CONCLUSIONS:
the rational and well-discussed use of the Swan-Ganz catheter was very useful for the handling of very ill patients with hemodynamic instability difficult to handle. This allowed a better interpretation of confusing physiopathological conditions, as well as applying opportune therapeutic methods and of difficult decision.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
CUMED
/
LILACS
Assunto principal:
Cateterismo de Swan-Ganz
/
Gravidade do Paciente
/
Hemodinâmica
/
Monitorização Fisiológica
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
/
Risk_factors_studies
Aspecto:
Patient_preference
Limite:
Humans
Idioma:
Es
Revista:
Arch. méd. Camaguey
Assunto da revista:
MEDICINA
Ano de publicação:
2014
Tipo de documento:
Article
País de afiliação:
Cuba
País de publicação:
Cuba