Your browser doesn't support javascript.
loading
[Validation and reliability of the 1,000 meter aerobic test]. / Validación y confiabilidad de la prueba aeróbica de 1,000 metros.
Díaz, F J; Montaño, J G; Melchor, M T; Guerrero, J H; Tovar, J A.
Afiliação
  • Díaz FJ; Departamento de Fisiología y Medicina, Universidad de Guanajuato, México.
Rev Invest Clin ; 52(1): 44-51, 2000.
Article em Es | MEDLINE | ID: mdl-10818810
BACKGROUND: In humans, measurement of maximum oxygen uptake is important because it is related to cardiovascular health. In Mexico there is scanty information in nationals and unfortunately such a data has been gathered from laboratory and field indirect methods ignoring reliability, validation and cross validation. PURPOSE: This study was designed to determine the validity and reliability of the 1,000 meters walk-run test in adults. METHODS: Fifty-one healthy subjects (31 men and 20 women) participated in four maximal tests; two in a laboratory on a treadmill for direct measurement of VO2max (L1 and L2) and twice in a track for distance walk-run time in 1,000 meters (C1 and C2). Values were analyzed by interclass correlation, Pearson product moment and "t" test. RESULTS: The VO2max in L1 y L2 were 2.67 and 2.70 L.min-1, (R = 0.97) and 44.2 and 46.2 mL.kg-1.min-1, meanwhile VO2max estimated from field were 44.2 and 46.2 mL.kg-1.min-1, (R = 0.98). Pearson correlation obtained from all subjects between laboratory and field test was of r = 0.88, without significant difference (P > 0.05). From those data we development the following equation: VO2max = 71.66-5.85 (t), where 71.66 and 5.85 are constants and t is the time employ in performing the test, R = -0.86, (p < 0.05). CONCLUSION: The 1,000 meters distance walk-run for time is highly reliable and valid test for estimation of VO2max in Mexican people. The test is safe, easy and short and can be administrated with a minimal amount of equipment. We propose its utilization in other population in order to perform cross validation.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consumo de Oxigênio / Teste de Esforço Limite: Adult / Female / Humans / Male Idioma: Es Revista: Rev Invest Clin Assunto da revista: MEDICINA Ano de publicação: 2000 Tipo de documento: Article País de publicação: México
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Consumo de Oxigênio / Teste de Esforço Limite: Adult / Female / Humans / Male Idioma: Es Revista: Rev Invest Clin Assunto da revista: MEDICINA Ano de publicação: 2000 Tipo de documento: Article País de publicação: México