Your browser doesn't support javascript.
loading
Determination of copper in powdered chocolate samples by slurry-sampling flame atomic-absorption spectrometry.
Dos Santos, Walter N L; da Silva, Erik G P; Fernandes, Marcelo S; Araujo, Rennan G O; Costa, Antônio C S; Vale, M G R; Ferreira, Sèrgio L C.
Afiliação
  • Dos Santos WN; Universidade Federal da Bahia, Instituto de Química, Núcleo de Excelência em Química Analítica da Bahia, Campus Universitário de Ondina, Salvador, 40170-290 Bahia, Brasil.
Anal Bioanal Chem ; 382(4): 1099-102, 2005 Jun.
Article em En | MEDLINE | ID: mdl-15891868
Chocolate is a complex sample with a high content of organic compounds and its analysis generally involves digestion procedures that might include the risk of losses and/or contamination. The determination of copper in chocolate is important because copper compounds are extensively used as fungicides in the farming of cocoa. In this paper, a slurry-sampling flame atomic-absorption spectrometric method is proposed for determination of copper in powdered chocolate samples. Optimization was carried out using univariate methodology involving the variables nature and concentration of the acid solution for slurry preparation, sonication time, and sample mass. The recommended conditions include a sample mass of 0.2 g, 2.0 mol L(-1) hydrochloric acid solution, and a sonication time of 15 min. The calibration curve was prepared using aqueous copper standards in 2.0 mol L(-1) hydrochloric acid. This method allowed determination of copper in chocolate with a detection limit of 0.4 microg g(-1) and precision, expressed as relative standard deviation (RSD), of 2.5% (n = 10) for a copper content of approximately 30 microg g(-1), using a chocolate mass of 0.2 g. The accuracy was confirmed by analyzing the certified reference materials NIST SRM 1568a rice flour and NIES CRM 10-b rice flour. The proposed method was used for determination of copper in three powdered chocolate samples, the copper content of which varied between 26.6 and 31.5 microg g(-1). The results showed no significant differences with those obtained after complete digestion, using a t-test for comparison.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrofotometria Atômica / Cacau / Cobre Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrofotometria Atômica / Cacau / Cobre Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha