Your browser doesn't support javascript.
loading
Peptide-coated nanotube-based biosensor for the detection of disease-specific autoantibodies in human serum.
Drouvalakis, Katerina A; Bangsaruntip, Sarunya; Hueber, Wolfgang; Kozar, Leland G; Utz, Paul J; Dai, Hongjie.
Afiliação
  • Drouvalakis KA; Division of Immunology and Rheumatology, Department of Medicine, Stanford University School of Medicine, Stanford, CA 94305, USA. drouvaka@cmgm.stanford.edu
Biosens Bioelectron ; 23(10): 1413-21, 2008 May 15.
Article em En | MEDLINE | ID: mdl-18222083
We demonstrate a label-free peptide-coated carbon nanotube-based immunosensor for the direct assay of human serum. A rheumatoid arthritis (RA)-specific (cyclic citrulline-containing) peptide, was immobilized to functionalized single-walled carbon nanotubes deposited on a quartz crystal microbalance (QCM) sensing crystal. Serum from RA patients was used to probe these nanotube-based sensors, and antibody binding was detected by QCM sensing. Specific antibody binding was also determined by comparing the assay of two serum control groups (normal and diseased sera), and the native unmodified peptide. The sensitivity of the nanotube-based sensor (detection in the femtomol range) was higher than that of the established ELISA and recently described microarray assay systems, detecting 34.4 and 37.5% more RA patients with anti-citrullinated peptide antibodies than those found by ELISA and microarray, respectively. There was also an 18.4 and 19.6% greater chance of a negative test being a true indicator of a person not having RA than by either ELISA or microarray, respectively. The performance of our label-free biosensor enables its application in the direct assay of sera in research and diagnostics.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos / Artrite Reumatoide / Autoanticorpos / Análise Química do Sangue / Técnicas Biossensoriais / Nanotubos Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos / Artrite Reumatoide / Autoanticorpos / Análise Química do Sangue / Técnicas Biossensoriais / Nanotubos Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Reino Unido