Your browser doesn't support javascript.
loading
Long and compact x-ray pathway for experiments requiring high coherent x-ray beams.
Hönnicke, Marcelo G; Kakuno, Edson M; Kellerman, Guinther; Mazzaro, Irineu; Abler, Daniel; Cusatis, Cesar.
Afiliação
  • Hönnicke MG; LORXI, Departamento de Fisica, Universidade Federal do Parana, Caixa Postal 19091, Curitiba, PR 81531-990, Brazil. marcelohonnicke@yahoo.com.br
Opt Express ; 16(13): 9284-9, 2008 Jun 23.
Article em En | MEDLINE | ID: mdl-18575492
A long x-ray pathway based on an x-ray back-diffraction cavity for coherent x-ray beam experiments is presented. In the present work, such a setup was tested and used for propagation-based x-ray phase contrast imaging (PBI). This setup showed to be useful for PBI purposes, with the advantage of being compact (3 m long) when compared with long x-ray synchrotron beamlines with dimensions from tens to hundreds of meters.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Difração de Raios X / Intensificação de Imagem Radiográfica / Óptica e Fotônica / Modelos Teóricos Idioma: En Revista: Opt Express Assunto da revista: OFTALMOLOGIA Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Difração de Raios X / Intensificação de Imagem Radiográfica / Óptica e Fotônica / Modelos Teóricos Idioma: En Revista: Opt Express Assunto da revista: OFTALMOLOGIA Ano de publicação: 2008 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos