Your browser doesn't support javascript.
loading
Influence of curing mode and time on degree of conversion of one conventional and two self-adhesive resin cements.
Aguiar, Thaiane Rodrigues; Di Francescantonio, Marina; Arrais, Cesar A G; Ambrosano, Gláucia Maria Bovi; Davanzo, Celso; Giannini, Marcelo.
Afiliação
  • Aguiar TR; State University of Campinas, Department of Restorative Dentistry, Piracicaba, SP, Brazil. thaianeaguiar@fop.unicamp.br
Oper Dent ; 35(3): 295-9, 2010.
Article em En | MEDLINE | ID: mdl-20533629
This study evaluated the effect of curing mode (auto- and dual-polymerizing mode) and time interval (5, 10 and 15 minutes) on the degree of conversion of resin cements. One conventional dual-cured resin cement (Panavia F 2.0 [Kuraray Medical Inc]) and two self-adhesive cements (RelyX Unicem [3M ESPE] and BisCem [BISCO, Inc]) were evaluated. The products (n = 5) were manipulated according to the manufacturer's instructions and applied to the surface of a horizontal attenuated reflectance unit attached to an infrared spectrometer. The materials were either light-cured for 40 seconds (dual-polymerizing mode) or allowed to auto-polymerize. The degree of conversion was calculated according to changes in the aliphatic-to-aromatic peak ratios prior to and 5, 10 and 15 minutes after light-activation or after mixing when the specimens were allowed to auto-polymerize. Data (%) were analyzed by two-way repeated measure ANOVA (curing mode and time interval) and Tukey's post-hoc test (alpha = 0.05%). The light-activating mode led to a higher degree of conversion values than the self-curing mode in self-adhesive cements (RelyX Unicem and BisCem), while there was no difference in the degree of conversion between the self- and light-cured groups of Panavia F 2.0 resin cement. All products showed a higher degree of conversion at 15 minutes postcuring than any other evaluation interval. The self-adhesive cements provide a higher degree of conversion values when light-activated. After 15 minutes of polymerization initiation, the degree of conversion was higher in all resin cements, regardless of the curing mode.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cimentos de Resina Limite: Humans Idioma: En Revista: Oper Dent Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cimentos de Resina Limite: Humans Idioma: En Revista: Oper Dent Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos