Your browser doesn't support javascript.
loading
Evaluation of chrono-impedance technique as transduction method for a carbon paste/glucose oxidase (CP/GOx) based glucose biosensor.
Mayorga Martinez, Carmen C; Treo, Ernesto F; Madrid, Rossana E; Felice, Carmelo C.
Afiliação
  • Mayorga Martinez CC; Departamento de Bioingeniería, Facultad de Ciencias Exactas y Tecnología, Universidad Nacional de Tucumán, CC 327-Correo Central, 4000 Tucumán, Argentina. carmen.mayorga@gmail.com
Biosens Bioelectron ; 26(4): 1239-44, 2010 Dec 15.
Article em En | MEDLINE | ID: mdl-20638830
The chrono-impedance technique (CIT) for real time determination of glucose concentration in a first generation glucose oxidase/carbon paste electrode was implemented. The biosensor was polarized with a signal composed of 900 mV DC potential and 50 mV(RMS) AC signal at 0.4 Hz. A frequency response analyzer was used to measure the complex impedance (magnitude |Z| and phase (Φ)) of the biosensor-bulk interface. Real time measurements were performed while glucose was added to the bulk within a concentration range of 0-40 mM. The cumulative impedance dose-response curves were used to construct calibration curves, both for magnitude and phase. The best fitting was obtained with a hyperbolic equation. Four biosensors were built obtaining five calibration curves for each of them. A single test measurement (unknown glucose concentration) was also obtained after each calibration procedure. Glucose concentrations were estimated with the calibration curves and also measured by colorimetry, the latter being the reference method. Besides, one-way ANOVA test evaluated repeatability. Difference between means was not statistically significant (p>0.01) for both magnitudes (|Z| and Φ). The Student's t-test assessed the differences significance, which produced in all cases p levels lower or equal than 0.44. Thus, CIT was proved to be a reliable method to measure glucose concentration in real time. Moreover, it showed high repeatability and compared well against colorimetry (r(2)=0.98).
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Glucose Tipo de estudo: Evaluation_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Argentina País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Glucose Tipo de estudo: Evaluation_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Argentina País de publicação: Reino Unido