Radiation dose for thoracic and coronary step-and-shoot CT using a 128-slice dual-source machine in infants and small children with congenital heart disease.
Pediatr Radiol
; 41(2): 244-9, 2011 Feb.
Article
em En
| MEDLINE
| ID: mdl-20821005
BACKGROUND: For coronary artery visualization, retrospective ECG-gated acquisition by dual-source computed tomography (DSCT) was superior to spiral non-ECG-gated acquisition in a paediatric population of congenital heart disease (CHD) patients. However, retrospective cardiac CT is associated with substantial radiation doses to the patient. Recently, DSCT with end-systolic reconstruction was found to be robust for imaging the coronary arteries in patients with high heart rates. OBJECTIVE: To evaluate step-and-shoot DSCT with end-systolic reconstruction for evaluating the heart, coronary arteries and other thoracic structures in young children with CHD. MATERIALS AND METHODS: All neonates and children younger than 6 years of age who were referred to our institution for CHD evaluation between September and October 2009 were included in the study. ECG-gated DSCT was performed in sequential prospective mode centred on the systolic phase identified by ECG analysis. To assess the radiation dose, we recorded the dose-length product (DLP) in mGy·cm and the effective dose in mSv estimated from the DLP. Overall image quality was evaluated using a 5-grade scoring system and was assessed by looking at cardiac and vascular structures. The image quality for the proximal and middle segments of the right and left coronary arteries was also evaluated using a 5-grade scale. RESULTS: Images of diagnostic quality (grade ≥ 3) were obtained in all 30 children with a mean image quality grade of 4.7 ± 0.6 (range, 3-5). Mean DLP was 5.7 ± 4.8 mGy*cm (range, 1-22 mGy cm) and mean effective radiation dose was 0.26 ± 0.16 mSv (range, 0.05-0.8 mSv). CONCLUSION: Prospective ECG-gated thoracic DSCT at end-systole usually provides adequate thoracic and coronary artery image quality in neonates, infants and young children with CHD, independent of heart rate. This new method is associated with lower radiation doses compared to previous literature (mean effective dose, 0.26 mSv).
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Doses de Radiação
/
Radiografia Torácica
/
Tomografia Computadorizada por Raios X
/
Angiografia Coronária
/
Técnicas de Imagem de Sincronização Cardíaca
/
Cardiopatias Congênitas
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
Limite:
Child, preschool
/
Female
/
Humans
/
Infant
/
Male
/
Newborn
Idioma:
En
Revista:
Pediatr Radiol
Ano de publicação:
2011
Tipo de documento:
Article
País de afiliação:
França
País de publicação:
Alemanha