A solid phase extraction followed by a liquid chromatography (LC)-tandem mass spectrometry (MS/MS) detection method for the confirmatory analysis of lincomycin (LIN), clindamycin (CLI), tilmicosin (TIM), erythromycin (ERI) and tylosin (TYL) residues in kidney were optimised and validated for monitoring and controlling the use of these antibiotics in food producing-animals. The method optimisation was carried out by testing changes in the extraction buffer pH and in the ammonium/acetonitrile concentrations on SPE eluent solutions. The optimised extraction procedure involved the extraction of the analytes with a pH 8 phosphate buffer, clean-up on a reversed-phase mixed-cation exchange cartridge, followed by the elution of the analytes in a 98:2 acetonitrile/ammonia solution, concentration in air flow and re-dissolved with an 1:1 methanol/water solution. The analytes were detected in an LC-MS/MS system in electrospray positive ionisation mode. The validation was performed according to the European Commission Decision 2002/657/EC. Linearity was established for all analytes using the method of least weighted squares and CCα values ranged from 5.3% to 21.1% higher than the minimum residue limit (MRL) values. The addition levels varied from 0.5 to 1.50 MRL for all analytes, with recoveries exceeding 92.5%. The relative standard deviations (RSD%) in terms of repeatability (n = 54) and reproducibility (n = 108) for all analytes were less than 21.6% and 21.4%, respectively. The uncertainties were calculated by simplified methods using the calibration curve uncertainty and the intermediate precision to obtain the combined measurement uncertainty. The results of the validation process demonstrated that this method is suitable for the quantification and confirmation of antibiotic residues for the Brazilian Residue and Contaminant Control Plan (PNCR).
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resíduos de Drogas / Lincomicina / Contaminação de Alimentos / Cromatografia Líquida / Macrolídeos / Espectrometria de Massas em Tandem / Antibacterianos Limite: Animals País/Região como assunto: America do sul / Brasil Idioma: En Revista: Food Addit Contam Part A Chem Anal Control Expo Risk Assess Assunto da revista: CIENCIAS DA NUTRICAO Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Resíduos de Drogas / Lincomicina / Contaminação de Alimentos / Cromatografia Líquida / Macrolídeos / Espectrometria de Massas em Tandem / Antibacterianos Limite: Animals País/Região como assunto: America do sul / Brasil Idioma: En Revista: Food Addit Contam Part A Chem Anal Control Expo Risk Assess Assunto da revista: CIENCIAS DA NUTRICAO Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido