To compare intraocular pressure (IOP) measurements obtained with Goldmann applanation (GAT) and dynamic contour tonometry (DCT) in a Mexican population. 40 glaucoma patients were included in this cross-sectional observational cohort study. IOP measurements were performed in the following order: DCT, ultrasonic pachymetry and GAT, with a 5-minute difference between each measurement, between 8 am and 2 pm. Only DCT measurements of good quality (Q ≤ 3) were accepted. GAT measurements were made three times with the same Goldmann tonometer, previously checked for calibration errors, and the mean was used for statistical purposes. The IOP (mean [standard deviation], 95 % confidence interval [CI]) measured with the Goldmann tonometer (13.2 [2.4], 12.4-14.0 mmHg) was significantly lower than that obtained with the DCT (18.4 [3.3], 17.0-19.2 mmHg), p < 0.0001. Pearson's correlation coefficients between CCT and IOP measured with GAT and DCT were (r = 0.24, 95 % CI = 0.07-0.52, p = 0.133) and (r = 0.13, 95 % CI = -0.19 to 0.43, p = 0.412), respectively. The concordance correlation coefficient between GAT and DCT was r c = 0.3, 95 % CI = 0.17-0.41). DCT seems to overestimate the IOP as compared to GAT. Additionally, although there was a good correlation between the IOP measurements assessed with either GAT or DCT, the agreement was poor.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tonometria Ocular / Glaucoma de Ângulo Aberto / Pressão Intraocular Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Mexico Idioma: En Revista: Int Ophthalmol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: México País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tonometria Ocular / Glaucoma de Ângulo Aberto / Pressão Intraocular Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Mexico Idioma: En Revista: Int Ophthalmol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: México País de publicação: Holanda