Your browser doesn't support javascript.
loading
Low-cost vibration sensor based on dual fiber Bragg gratings and light intensity measurement.
Appl Opt ; 52(27): 6782-7, 2013 Sep 20.
Article em En | MEDLINE | ID: mdl-24085178
A vibration monitoring system based on light intensity measurement has been constructed, and the designed accelerometer is based on steel cantilever frame and dual fiber Bragg gratings (FBGs). By using numerical simulations for the dual FBGs, the dependence relationship of the area of main lobes on the difference of initial central wavelengths is obtained and the most optimal choice for the initial value and the vibration amplitude of the difference of central wavelengths of two FBGs is suggested. The vibration monitoring experiments are finished, and the measured data are identical to the simulated results.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Health_economic_evaluation Idioma: En Revista: Appl Opt Ano de publicação: 2013 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Health_economic_evaluation Idioma: En Revista: Appl Opt Ano de publicação: 2013 Tipo de documento: Article País de publicação: Estados Unidos