Your browser doesn't support javascript.
loading
Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula.
Jang, Jinhee; Schmitt, Peter; Kim, Bom-yi; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin; Kim, Inseong; Paek, Munyoung; Kim, Bum-soo.
Afiliação
  • Jang J; Department of Radiology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul, 137-701, South Korea.
Neuroradiology ; 56(4): 305-14, 2014 Apr.
Article em En | MEDLINE | ID: mdl-24526141
INTRODUCTION: This study aimed to evaluate the feasibility of non-contrast-enhanced 4D magnetic resonance angiography (NCE 4D MRA) with signal targeting with alternative radiofrequency (STAR) spin labeling and variable flip angle (VFA) sampling in the assessment of dural arteriovenous fistula (DAVF) in the transverse sinus. METHODS: Nine patients underwent NCE 4D MRA for the evaluation of DAVF in the transverse sinus at 3 T. One patient was examined twice, once before and once after the interventional treatment. All patients also underwent digital subtraction angiography (DSA) and/or contrast-enhanced magnetic resonance angiography (CEMRA). For the acquisition of NCE 4D MRA, a STAR spin tagging method was used, and a VFA sampling was applied in the data readout module instead of a constant flip angle. Two readers evaluated the NCE 4D MRA data for the diagnosis of DAVF and its type with consensus. The results were compared with those from DSA and/or CEMRA. RESULTS: All patients underwent NCE 4D MRA without any difficulty. Among seven patients with patent DAVFs, all cases showed an early visualization of the transverse sinus on NCE 4D MRA. Except for one case, the type of DAVF of NCE 4D MRA was agreed with that of reference standard study. Cortical venous reflux (CVR) was demonstrated in two cases out of three patients with CVR. CONCLUSION: NCE 4D MRA with STAR tagging and VFA sampling is technically and clinically feasible and represents a promising technique for assessment of DAVF in the transverse sinus. Further technical developments should aim at improvements of spatial and temporal coverage.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Malformações Arteriovenosas Intracranianas / Fístula Arteriovenosa / Angiografia por Ressonância Magnética / Imageamento Tridimensional / Seios Transversos / Técnicas de Imagem de Sincronização Cardíaca Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Neuroradiology Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Coréia do Sul País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Malformações Arteriovenosas Intracranianas / Fístula Arteriovenosa / Angiografia por Ressonância Magnética / Imageamento Tridimensional / Seios Transversos / Técnicas de Imagem de Sincronização Cardíaca Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Neuroradiology Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Coréia do Sul País de publicação: Alemanha