Your browser doesn't support javascript.
loading
A simple and rapid screening method for sulfonamides in honey using a flow injection system coupled to a liquid waveguide capillary cell.
Catelani, Tiago Augusto; Tóth, Ildikó Vargáné; Lima, José L F C; Pezza, Leonardo; Pezza, Helena Redigolo.
Afiliação
  • Catelani TA; Instituto de Química, Universidade Estadual Paulista "Julio de Mesquita Filho", UNESP, R. Prof. Francisco Degni 55, PO Box 355, 14800-900 Araraquara, SP, Brazil.
  • Tóth IV; REQUIMTE, Laboratório de Química Aplicada, Departamento de Química, Faculdade de Farmácia, Universidade do Porto, Rua de Jorge Viterbo Ferreira n.° 228, Porto 4050-313, Portugal.
  • Lima JL; REQUIMTE, Laboratório de Química Aplicada, Departamento de Química, Faculdade de Farmácia, Universidade do Porto, Rua de Jorge Viterbo Ferreira n.° 228, Porto 4050-313, Portugal.
  • Pezza L; Instituto de Química, Universidade Estadual Paulista "Julio de Mesquita Filho", UNESP, R. Prof. Francisco Degni 55, PO Box 355, 14800-900 Araraquara, SP, Brazil.
  • Pezza HR; Instituto de Química, Universidade Estadual Paulista "Julio de Mesquita Filho", UNESP, R. Prof. Francisco Degni 55, PO Box 355, 14800-900 Araraquara, SP, Brazil. Electronic address: hrpezza@iq.unesp.br.
Talanta ; 121: 281-7, 2014 Apr.
Article em En | MEDLINE | ID: mdl-24607139
A rapid and simple screening method was developed for the determination of sulfonamides in honey samples by flow injection analysis (FIA) coupled to a liquid waveguide capillary cell. The proposed method is based on the reaction between sulfonamides and p-dimethylaminocinnamaldehyde (p-DAC) in the presence of sodium dodecylsulate (SDS) in dilute acid medium (hydrochloric acid), with the reaction product being measured spectrophotometrically at λ(max) = 565 nm. Experimental design methodology was used to optimize the analytical conditions. The proposed technique was applied to the determination of sulfonamides (sulfaquinoxaline, sulfadimethoxine, and sulfathiazole) in honey samples, in a concentration range from 6.00 × 10(-3) to 1.15 × 10(-1)mg L(-1). The detection (LOD) and quantification (LOQ) limits were 1.66 × 10(-3) and 5.54 × 10(-3)mg L(-1), respectively. Positive and false positive samples were also analyzed by a confirmatory HPLC method. The proposed system enables the screening of sulfonamides in honey samples with a low number of false positive results, with fast response therefore offers a new tool for consumer protection.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sulfonamidas / Análise de Injeção de Fluxo / Mel Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Revista: Talanta Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sulfonamidas / Análise de Injeção de Fluxo / Mel Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Revista: Talanta Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda