Your browser doesn't support javascript.
loading
A novel approach to bar adsorptive microextraction: Cork as extractor phase for determination of benzophenone, triclocarban and parabens in aqueous samples.
Dias, Adriana Neves; da Silva, Ana Cristine; Simão, Vanessa; Merib, Josias; Carasek, Eduardo.
Afiliação
  • Dias AN; Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis 88040900, SC, Brazil.
  • da Silva AC; Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis 88040900, SC, Brazil.
  • Simão V; Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis 88040900, SC, Brazil.
  • Merib J; Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis 88040900, SC, Brazil.
  • Carasek E; Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis 88040900, SC, Brazil. Electronic address: eduardo.carasek@ufsc.br.
Anal Chim Acta ; 888: 59-66, 2015 Aug 12.
Article em En | MEDLINE | ID: mdl-26320959
This study describes the use of cork as a new coating for bar adsorptive microextraction (BAµE) and its application in determining benzophenone, triclocarban and parabens in aqueous samples by HPLC-DAD. In this study bars with 7.5 and 15 mm of length were used. The extraction and liquid desorption steps for BAµE were optimized employing multivariate and univariate procedures. The desorption time and solvent used for liquid desorption were optimized by univariate and multivariate studies, respectively. For the extraction step the sample pH was optimized by univariate experiments while the parameters extraction time and ionic strength were evaluated using the Doehlert design. The optimum extraction conditions were sample pH 5.5, NaCl concentration 25% and extraction time 90 min. Liquid desorption was carried out for 30 min with 250 µL (bar length of 15 mm) or 100 µL (bar length of 7.5 mm) of ACN:MeOH (50:50, v/v). The quantification limits varied between 1.6 and 20 µg L(-1) (bar length of 15 mm) and 0.64 and 8 µg L(-1) (bar length of 7.5 mm). The linear correlation coefficients were higher than 0.98 for both bars. The method with 7.5 mm bar length showed recovery values between 65 and 123%. The bar-to-bar reproducibility and the repeatability were lower than 13% (n = 2) and 14% (n = 3), respectively.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Parabenos / Poluentes Químicos da Água / Benzofenonas / Carbanilidas / Phellodendron / Microextração em Fase Líquida Tipo de estudo: Evaluation_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Parabenos / Poluentes Químicos da Água / Benzofenonas / Carbanilidas / Phellodendron / Microextração em Fase Líquida Tipo de estudo: Evaluation_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda