Your browser doesn't support javascript.
loading
Multicenter analytical performance evaluation of a fully automated anti-Müllerian hormone assay and reference interval determination.
Anckaert, E; Öktem, M; Thies, A; Cohen-Bacrie, M; Daan, N M P; Schiettecatte, J; Müller, C; Topcu, D; Gröning, A; Ternaux, F; Engel, C; Engelmann, S; Milczynski, C.
Afiliação
  • Anckaert E; Laboratory of Hormonology and Tumour Markers, Universitair Ziekenhuis Brussel, Free University of Brussels (VUB), Brussels, Belgium. Electronic address: ellen.anckaert@uzbrussel.be.
  • Öktem M; Duzen Laboratories Group, Tunus Cad. No. 95, Kavaklidere, Ankara, Turkey.
  • Thies A; MVZ wagnerstibbe für Laboratoriumsmedizin and Pathologie GmbH, Georgstraße 50, 30159 Hannover, Germany.
  • Cohen-Bacrie M; Laboratoire Eylau Saint Didier, 55, rue Saint Didier, 75116 Paris, France.
  • Daan NM; Department of Reproductive Medicine and Gynecology, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht, The Netherlands.
  • Schiettecatte J; Laboratory of Hormonology and Tumour Markers, Universitair Ziekenhuis Brussel, Free University of Brussels (VUB), Brussels, Belgium.
  • Müller C; Limbach Laboratory, Medical Care Center, Im Breitspiel 15, 69126 Heidelberg, Germany.
  • Topcu D; Duzen Laboratories Group, Tunus Cad. No. 95, Kavaklidere, Ankara, Turkey.
  • Gröning A; MVZ wagnerstibbe für Laboratoriumsmedizin and Pathologie GmbH, Georgstraße 50, 30159 Hannover, Germany.
  • Ternaux F; Laboratoire Eylau Saint Didier, 55, rue Saint Didier, 75116 Paris, France.
  • Engel C; Roche Diagnostics GmbH, Nonnenwald 2, 82377 Penzberg, Germany.
  • Engelmann S; Roche Diagnostics GmbH, Sandhofer Str. 116, 68305 Mannheim, Germany.
  • Milczynski C; Limbach Laboratory, Medical Care Center, Im Breitspiel 15, 69126 Heidelberg, Germany.
Clin Biochem ; 49(3): 260-7, 2016 Feb.
Article em En | MEDLINE | ID: mdl-26500002
OBJECTIVES: Anti-Müllenria hormone (AMH) is an established biomarker for assessing ovarian reserve and predicting response to controlled ovarian stimulation. Its routine clinical use is hampered by the variability and low-throughput of available enzyme-linked immunosorbent assays (ELISA). The presented study examined if a fully automated AMH electrochemiluminescence assay (ECLIA; Elecsys® AMH assay, Roche Diagnostics) was suitable for measuring AMH levels in healthy women and in those diagnosed with polycystic ovary syndrome (PCOS). DESIGN AND METHODS: Five European laboratories evaluated the Elecsys® AMH assay independently under routine conditions over eight months. Within-run imprecision, repeatability, intermediate precision, linearity and functional sensitivity were assessed. The Elecsys® AMH assay was compared to a manual ELISA microtiter plate format test (AMH Gen II ELISA, modified version; Beckman Coulter Inc.) using 1729 routine serum samples. AMH reference intervals were determined in 887 healthy women with regular menstrual cycle aged 20­50 years, and 149 women diagnosed with PCOS. RESULTS: The fully automated Elecsys® AMH assay showed excellent precision, linearity, and functional sensitivity. The coefficient of variation was 1.8% for repeatability and 4.4% for intermediate precision. Values measured with the Elecsys® AMH assay were highly correlated with the manual ELISA method (modified version) but 24­28% lower. Reference intervals showed the expected AMH decline with age in healthy women and increased AMH levels in women with PCOS. CONCLUSIONS: The Elecsys® AMH assay demonstrated good precision under routine conditions, and is suitable for determining AMH levels in serum and lithium-heparin plasma.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaio de Imunoadsorção Enzimática / Hormônio Antimülleriano / Medições Luminescentes Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Guideline / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Middle aged Idioma: En Revista: Clin Biochem Ano de publicação: 2016 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaio de Imunoadsorção Enzimática / Hormônio Antimülleriano / Medições Luminescentes Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Guideline / Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Middle aged Idioma: En Revista: Clin Biochem Ano de publicação: 2016 Tipo de documento: Article País de publicação: Estados Unidos