Your browser doesn't support javascript.
loading
Measurement of skeletal muscle perfusion dynamics with pseudo-continuous arterial spin labeling (pCASL): Assessment of relative labeling efficiency at rest and during hyperemia, and comparison to pulsed arterial spin labeling (PASL).
Englund, Erin K; Rodgers, Zachary B; Langham, Michael C; Mohler, Emile R; Floyd, Thomas F; Wehrli, Felix W.
Afiliação
  • Englund EK; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA. eenglund@mail.med.upenn.edu.
  • Rodgers ZB; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Langham MC; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Mohler ER; Department of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Floyd TF; Department of Anesthesiology, Stony Brook University, Stony Brook, New York, USA.
  • Wehrli FW; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
J Magn Reson Imaging ; 44(4): 929-39, 2016 10.
Article em En | MEDLINE | ID: mdl-27043039
PURPOSE: To compare calf skeletal muscle perfusion measured with pulsed arterial spin labeling (PASL) and pseudo-continuous arterial spin labeling (pCASL) methods, and to assess the variability of pCASL labeling efficiency in the popliteal artery throughout an ischemia-reperfusion paradigm. MATERIALS AND METHODS: At 3T, relative pCASL labeling efficiency was experimentally assessed in five subjects by measuring the signal intensity of blood in the popliteal artery just distal to the labeling plane immediately following pCASL labeling or control preparation pulses, or without any preparation pulses throughout separate ischemia-reperfusion paradigms. The relative label and control efficiencies were determined during baseline, hyperemia, and recovery. In a separate cohort of 10 subjects, pCASL and PASL sequences were used to measure reactive hyperemia perfusion dynamics. RESULTS: Calculated pCASL labeling and control efficiencies did not differ significantly between baseline and hyperemia or between hyperemia and recovery periods. Relative to the average baseline, pCASL label efficiency was 2 ± 9% lower during hyperemia. Perfusion dynamics measured with pCASL and PASL did not differ significantly (P > 0.05). Average leg muscle peak perfusion was 47 ± 20 mL/min/100g or 50 ± 12 mL/min/100g, and time to peak perfusion was 25 ± 3 seconds and 25 ± 7 seconds from pCASL and PASL data, respectively. Differences of further metrics parameterizing the perfusion time course were not significant between pCASL and PASL measurements (P > 0.05). CONCLUSION: No change in pCASL labeling efficiency was detected despite the almost 10-fold increase in average blood flow velocity in the popliteal artery. pCASL and PASL provide precise and consistent measurement of skeletal muscle reactive hyperemia perfusion dynamics. J. MAGN. RESON. IMAGING 2016;44:929-939.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Velocidade do Fluxo Sanguíneo / Processamento de Sinais Assistido por Computador / Interpretação de Imagem Assistida por Computador / Músculo Esquelético / Angiografia por Ressonância Magnética / Hiperemia Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Velocidade do Fluxo Sanguíneo / Processamento de Sinais Assistido por Computador / Interpretação de Imagem Assistida por Computador / Músculo Esquelético / Angiografia por Ressonância Magnética / Hiperemia Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos