Your browser doesn't support javascript.
loading
Evaluation of the methylene blue addition in binary polymeric systems composed by poloxamer 407 and Carbopol 934P using quality by design: rheological, textural, and mucoadhesive analysis.
Junqueira, Mariana Volpato; Borghi-Pangoni, Fernanda Belincanta; Ferreira, Sabrina Barbosa de Souza; Bruschi, Marcos Luciano.
Afiliação
  • Junqueira MV; a Department of Pharmacy, Laboratory of Research and Development of Drug Delivery Systems , State University of Maringá, Avenida Colombo , Maringá , PR , Brazil.
  • Borghi-Pangoni FB; a Department of Pharmacy, Laboratory of Research and Development of Drug Delivery Systems , State University of Maringá, Avenida Colombo , Maringá , PR , Brazil.
  • Ferreira SB; a Department of Pharmacy, Laboratory of Research and Development of Drug Delivery Systems , State University of Maringá, Avenida Colombo , Maringá , PR , Brazil.
  • Bruschi ML; a Department of Pharmacy, Laboratory of Research and Development of Drug Delivery Systems , State University of Maringá, Avenida Colombo , Maringá , PR , Brazil.
Drug Dev Ind Pharm ; 42(12): 2009-2019, 2016 Dec.
Article em En | MEDLINE | ID: mdl-27161762
This study describes the investigation about the physicochemical behavior of methylene blue (Mb) addition to systems containing poloxamer 407 (Polox), Carbopol 934P (Carb), intended to be locally used by photodynamic therapy. A factorial design 23 (plus center point) was used to analyze the rheological, mucoadhesive and textural properties of the preparations. Systems containing the lower concentrations of Polox (15 and 17.5%, w/w) exhibited pseudoplastic flow and low degrees of rheopexy. On the other hand, at higher Polox concentration (20%, w/w) the systems display plastic flow and thixotropy. Carb and Mb exhibited a negative influence for the consistency and flow behavior index, due to the interaction between them. For most of the formulations, the increase of Polox and Mb content significantly increased storage modulus, loss modulus and dynamic viscosity. The systems display a sol-gel transition temperature, existing as a liquid at room temperature and gel at 29-37 °C. Increasing the temperature and the polymer concentration, the compressional properties of systems significantly increased. The mucoadhesion was noted to all formulations, except to systems composed by 15% (w/w) of Polox. The analyses enabled to understand and predict the performance of formulations and the polymer-Mb interactions, tailoring to the suit systems (Polox/Carb/Mb): 17.5/0.50/0.20 and 20/0.15/0.25.
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Drug Dev Ind Pharm Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Drug Dev Ind Pharm Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido