Your browser doesn't support javascript.
loading
Determination of chloride in brazilian crude oils by ion chromatography after extraction induced by emulsion breaking.
Robaina, Nicolle F; Feiteira, Fernanda N; Cassella, Alessandra R; Cassella, Ricardo J.
Afiliação
  • Robaina NF; Departamento de Química Analítica, Universidade Federal Fluminense, Outeiro de São João Batista s/n, Centro, Niterói/RJ, 24020-141, Brazil.
  • Feiteira FN; Departamento de Química Analítica, Universidade Federal Fluminense, Outeiro de São João Batista s/n, Centro, Niterói/RJ, 24020-141, Brazil.
  • Cassella AR; PETROBRAS, CENPES, PDEDS/QM, Av. Horácio Macedo 950, Ilha do Fundão, Rio de Janeiro/RJ 21941-915, Brazil.
  • Cassella RJ; Departamento de Química Analítica, Universidade Federal Fluminense, Outeiro de São João Batista s/n, Centro, Niterói/RJ, 24020-141, Brazil. Electronic address: cassella@vm.uff.br.
J Chromatogr A ; 1458: 112-7, 2016 Aug 05.
Article em En | MEDLINE | ID: mdl-27388656
The present paper reports on the development of a novel extraction induced by emulsion breaking (EIEB) method for the determination of chloride in crude oils. The proposed method was based on the formation and breaking of oil-in-water emulsions with the samples and the consequential transference of the highly water-soluble chloride to the aqueous phase during emulsion breaking, which was achieved by centrifugation. The determination of chloride in the extracts was performed by ion chromatography (IC) with conductivity detection. Several parameters (oil phase:aqueous phase ratio, crude oil:mineral oil ratio, shaking time and type and concentration of surfactant) that could affect the performance of the method were evaluated. Total extraction of chloride from samples could be achieved when 1.0g of oil phase (0.5g of sample+0.5g of mineral oil) was emulsified in 5mL of a 2.5% (m/v) solution of Triton X-114. The obtained emulsion was shaken for 60min and broken by centrifugation for 5min at 5000rpm. The separated aqueous phase was collected, filtered and diluted before analysis by IC. Under these conditions, the limit of detection was 0.5µgg(-1) NaCl and the limit of quantification was 1.6µgg(-1) NaCl. We applied the method to the determination of chloride in six Brazilian crude oils and the results did not differ statistically from those obtained by the ASTM D6470 method when the paired Student-t-test, at 95% confidence level, was applied.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Petróleo / Cloretos / Cromatografia País/Região como assunto: America do sul / Brasil Idioma: En Revista: J Chromatogr A Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Petróleo / Cloretos / Cromatografia País/Região como assunto: America do sul / Brasil Idioma: En Revista: J Chromatogr A Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda