Your browser doesn't support javascript.
loading
Combined Tenodesis-Capsulodesis for Scapholunate Instability: Minimum 2-Year Follow-Up.
De Carli, Pablo; Donndorff, Agustin G; Torres, Miguel Tovar; Boretto, Jorge G; Gallucci, Gerardo L.
Afiliação
  • De Carli P; Hospital Italiano de Buenos Aires, "Carlos E. Ottolenghi" Institute, Hand Surgery and Upper Extremity Center, Buenos Aires, Argentina.
  • Donndorff AG; Hospital Italiano de Buenos Aires, "Carlos E. Ottolenghi" Institute, Hand Surgery and Upper Extremity Center, Buenos Aires, Argentina.
  • Torres MT; Hospital Italiano de Buenos Aires, "Carlos E. Ottolenghi" Institute, Hand Surgery and Upper Extremity Center, Buenos Aires, Argentina.
  • Boretto JG; Hospital Italiano de Buenos Aires, "Carlos E. Ottolenghi" Institute, Hand Surgery and Upper Extremity Center, Buenos Aires, Argentina.
  • Gallucci GL; Hospital Italiano de Buenos Aires, "Carlos E. Ottolenghi" Institute, Hand Surgery and Upper Extremity Center, Buenos Aires, Argentina.
J Wrist Surg ; 6(1): 11-21, 2017 Feb.
Article em En | MEDLINE | ID: mdl-28119791
Background The aim of this study is to evaluate the clinical and radiological midterm results of a combined dorsal tenodesis-capsulodesis for static and reducible scapholunate dissociation (SLD). Patients and Methods We evaluated 20 of 22 consecutive patients with static SLD minimum with follow-up of 2 years operated between 2003 and 2012. The mean age was 40 years (range: 23-65 years). Seventeen were men. Final evaluation included comparative wrist range of motion (ROM) and grip strength, pre- and postoperative pain and function by visual analog scale, and QuickDASH and Wrightington scores. Radiographs included preoperative, early postoperative, and final X-rays. Scapholunate space (SLS) and scapholunate and radioscaphoid angles (SLA and RSA) were measured. Statistical significance was evaluated with Student t-test, considered significant when p < 0.05. Results Mean follow-up was 67 months (range: 24-126 months). Mean final ROM was: flexion 55 degrees (73%), extension 62 degrees (90%), radial deviation 19 degrees (82%), and ulnar deviation 44 degrees (90%). Mean grip strength was 44 kg (92%). Pain at rest improved from 3.4 to 0.5 (p < 0.05). Pain in activity improved from 7 to 1.7 (p < 0.05). Final function was 8.5 (preoperative, 5.2; p < 0.05). Mean QuickDASH score improved from 38 to 8 (p < 0.05). Functional Wrightington score was as follows: 13 excellent, 3 good, 1 regular, and 3 poor. There were three postoperative minor complications. Radiological results (preoperative/early postoperative/final follow-up) were as follows: SLS, 4.7/1.6/1.8 mm; and SLA, 60/50/62 degrees; RSA, 39/45/37 degrees. Four patients showed arthritic changes (two SLAC wrist). Conclusion The clinical and radiological results with more than 2-year follow-up suggest that this technique may be effective, reproducible, and safe for symptomatic static and reducible SLD. Level of Evidence Level IV, case series.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Wrist Surg Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Argentina País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Wrist Surg Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Argentina País de publicação: Estados Unidos