Your browser doesn't support javascript.
loading
Mechanical stability of 2-plate versus 4-plate osteosynthesis in advancement Le Fort I osteotomy. An in vitro study.
Pozzer, L; Olate, S; Cavalieri-Pereira, L; Navarro, P; de Albergaría Barbosa, J R.
Afiliação
  • Pozzer L; Division of Oral and Maxillofacial Surgery, State University of Campinas, Piracicaba, SP, Brazil.
  • Olate S; Division of Oral and Maxillofacial Surgery, Universidad de La Frontera, Temuco, Chile; Center for Biomedical Research, Universidad Autónoma de Chile, Temuco, Chile. Electronic address: sergio.olate@ufrontera.cl.
  • Cavalieri-Pereira L; Division of Oral and Maxillofacial Surgery, State University of Campinas, Piracicaba, SP, Brazil.
  • Navarro P; Division of Oral and Maxillofacial Surgery, Universidad de La Frontera, Temuco, Chile.
  • de Albergaría Barbosa JR; Division of Oral and Maxillofacial Surgery, State University of Campinas, Piracicaba, SP, Brazil.
J Stomatol Oral Maxillofac Surg ; 118(1): 2-4, 2017 Feb.
Article em En | MEDLINE | ID: mdl-28330569
INTRODUCTION: Stability in orthognathic surgery is nowadays considered as efficient and adequate. The objective of this study was to determine and to compare the mechanical resistance to vertical load of a Le Fort I advancement osteotomy stabilized by mean of two different osteosynthesis techniques, one using two 10-hole pre-bent T-shaped plates, the other using four manually bent 4-hole L- and J-shaped plates. MATERIEL AND METHODS: Standardized Le Fort I advancement osteotomies have been made on polyurethane models. The maxillary advancement was 5mm. Two groups of five models each were created. Group 1 was stabilized by mean of two 10-hole pre-bent T-shaped plates fixed by monocortical screws in the paranasal region. Group 2 was stabilized by mean of manually bent four 4-hole L-shaped plates fixed monocortical screws in the zygomatic and paranasal regions. A testing machine was used to load vertically the models at the range of 1mm/min linear displacement until peak load and system failure. Statistical analysis was realized using ANOVA and t-test, considering P as significant if <0.005. RESULTS: The maximal tolerated load was 15N in group 1and 42.71N in group 2 (P=0.003). DISCUSSION: The use of two T-shaped 10-holes pre-bent plates allows for less resistance in vertical loading than the use of four 4-holes manually bent L-shaped plates.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estresse Mecânico / Placas Ósseas / Osteotomia de Le Fort / Fixação Interna de Fraturas Limite: Humans Idioma: En Revista: J Stomatol Oral Maxillofac Surg Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estresse Mecânico / Placas Ósseas / Osteotomia de Le Fort / Fixação Interna de Fraturas Limite: Humans Idioma: En Revista: J Stomatol Oral Maxillofac Surg Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: França