Your browser doesn't support javascript.
loading
Detection of trace levels of organophosphate pesticides using an electronic tongue based on graphene hybrid nanocomposites.
Facure, Murilo H M; Mercante, Luiza A; Mattoso, Luiz H C; Correa, Daniel S.
Afiliação
  • Facure MHM; National Laboratory for Nanotechnology in Agribusiness (LNNA), Embrapa Instrumentation, 13560-970 São Carlos, SP, Brazil; Center for Exact Sciences and Technology, Federal University of São Carlos (UFSCar), 13565-905 São Carlos, SP, Brazil.
  • Mercante LA; National Laboratory for Nanotechnology in Agribusiness (LNNA), Embrapa Instrumentation, 13560-970 São Carlos, SP, Brazil.
  • Mattoso LHC; National Laboratory for Nanotechnology in Agribusiness (LNNA), Embrapa Instrumentation, 13560-970 São Carlos, SP, Brazil.
  • Correa DS; National Laboratory for Nanotechnology in Agribusiness (LNNA), Embrapa Instrumentation, 13560-970 São Carlos, SP, Brazil; Center for Exact Sciences and Technology, Federal University of São Carlos (UFSCar), 13565-905 São Carlos, SP, Brazil. Electronic address: daniel.correa@embrapa.br.
Talanta ; 167: 59-66, 2017 May 15.
Article em En | MEDLINE | ID: mdl-28340765
Organophosphate (OP) compounds impose significant strains on public health, environmental/food safety and homeland security, once they have been widely used as pesticides and insecticides and also display potential to be employed as chemical warfare agents by terrorists. In this context, the development of sensitive and reliable chemical sensors that would allow in-situ measurements of such contaminants is highly pursued. Here we report on a free-enzyme impedimetric electronic tongue (e-tongue) used in the analysis of organophosphate pesticides comprising four sensing units based on graphene hybrid nanocomposites. The nanocomposites were prepared by reduction of graphene oxide in the presence of conducting polymers (PEDOT:PSS and polypyrrole) and gold nanoparticles (AuNPs), which were deposited by drop casting onto gold interdigitated electrodes. Impedance spectroscopy measurements were collected in triplicate for each sample analyzed, and the electrical resistance data were treated by Principal Component Analysis (PCA), revealing that the system was able to discriminate OPs at nanomolar concentrations. In addition, the electronic tongue system could detect OPs in real samples, where relations between the principal components and the variation of pesticides in a mixture were established, proving to be useful to analyze and monitor mixtures of OP pesticides. The materials employed provided sensing units with high specific surface area and high conductivity, yielding the development of a sensor with suitable stability, good reproducibility, and high sensitivity towards pesticide samples, being able to discriminate concentrations as low as 0.1nmolL-1. Our results indicate that the e-tongue system can be used as a rapid, simple and low cost alternative in the analyses of OPs pesticide solutions below the concentration range permitted by legislation of some countries.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organofosforados / Praguicidas / Nanocompostos / Limite de Detecção / Nariz Eletrônico / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Talanta Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organofosforados / Praguicidas / Nanocompostos / Limite de Detecção / Nariz Eletrônico / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Talanta Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda