Your browser doesn't support javascript.
loading
Accurate Region-of-Interest Recovery Improves the Measurement of the Cell Migration Rate in the In Vitro Wound Healing Assay.
Bedoya, Cesar; Cardona, Andrés; Galeano, July; Cortés-Mancera, Fabián; Sandoz, Patrick; Zarzycki, Artur.
Afiliação
  • Bedoya C; 1 Facultad de Ingenierías/Grupo de Investigación en Materiales Avanzados y Energía MatyEr/Línea Biomateriales y Electromedicina, Instituto Tecnológico Metropolitano ITM, Medellín, Antioquia, Colombia.
  • Cardona A; 2 Facultad de Ciencias Exactas y Aplicadas/Grupo de Investigación e Innovación Biomédica-GIB/Laboratorio de Ciencias Biomédicas, Instituto Tecnológico Metropolitano ITM, Medellín, Antioquia, Colombia.
  • Galeano J; 1 Facultad de Ingenierías/Grupo de Investigación en Materiales Avanzados y Energía MatyEr/Línea Biomateriales y Electromedicina, Instituto Tecnológico Metropolitano ITM, Medellín, Antioquia, Colombia.
  • Cortés-Mancera F; 2 Facultad de Ciencias Exactas y Aplicadas/Grupo de Investigación e Innovación Biomédica-GIB/Laboratorio de Ciencias Biomédicas, Instituto Tecnológico Metropolitano ITM, Medellín, Antioquia, Colombia.
  • Sandoz P; 3 Department of Applied Mechanics, FEMTO-ST Institute, University Bourgogne Franche-Comté, CNRS/UFC/ENSMM/UTBM, Besançon, France.
  • Zarzycki A; 4 Facultad de Ingenierías/Grupo de Investigación en Automática, Electrónica y Ciencias Computacionales/Línea Sistemas de Control y Robótica, Instituto Tecnológico Metropolitano ITM, Medellín, Antioquia, Colombia.
SLAS Technol ; 22(6): 626-635, 2017 12.
Article em En | MEDLINE | ID: mdl-28692403
The wound healing assay is widely used for the quantitative analysis of highly regulated cellular events. In this essay, a wound is voluntarily produced on a confluent cell monolayer, and then the rate of wound reduction (WR) is characterized by processing images of the same regions of interest (ROIs) recorded at different time intervals. In this method, sharp-image ROI recovery is indispensable to compensate for displacements of the cell cultures due either to the exploration of multiple sites of the same culture or to transfers from the microscope stage to a cell incubator. ROI recovery is usually done manually and, despite a low-magnification microscope objective is generally used (10x), repositioning imperfections constitute a major source of errors detrimental to the WR measurement accuracy. We address this ROI recovery issue by using pseudoperiodic patterns fixed onto the cell culture dishes, allowing the easy localization of ROIs and the accurate quantification of positioning errors. The method is applied to a tumor-derived cell line, and the WR rates are measured by means of two different image processing software. Sharp ROI recovery based on the proposed method is found to improve significantly the accuracy of the WR measurement and the positioning under the microscope.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cicatrização / Processamento de Imagem Assistida por Computador / Movimento Celular / Técnicas de Cultura de Células / Imagem Óptica / Microscopia Limite: Humans Idioma: En Revista: SLAS Technol Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cicatrização / Processamento de Imagem Assistida por Computador / Movimento Celular / Técnicas de Cultura de Células / Imagem Óptica / Microscopia Limite: Humans Idioma: En Revista: SLAS Technol Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Colômbia País de publicação: Estados Unidos