Your browser doesn't support javascript.
loading
Safety and efficacy of hydroxyapatite scaffold in the prevention of jaw osteonecrosis in vivo.
de Almeida, Adriana Duarte; Leite, Fernanda Gomes; Chaud, Marco Vinícius; Rebelo, Márcia de Araújo; Borges, Liliane Cristine Ferreira de Souza; Viroel, Fabia Judice Marques; Hataka, Alessandre; Grotto, Denise.
Afiliação
  • de Almeida AD; Laboratory of Toxicological Research, University of Sorocaba (Uniso), Sorocaba, São Paulo, Brazil.
  • Leite FG; Laboratory of Toxicological Research, University of Sorocaba (Uniso), Sorocaba, São Paulo, Brazil.
  • Chaud MV; Laboratory of Biomaterials and Nanotechnology, University of Sorocaba (Uniso), Sorocaba, São Paulo, Brazil.
  • Rebelo MA; Laboratory of Biomaterials and Nanotechnology, University of Sorocaba (Uniso), Sorocaba, São Paulo, Brazil.
  • Borges LCFS; Laboratory of Biomaterials and Nanotechnology, University of Sorocaba (Uniso), Sorocaba, São Paulo, Brazil.
  • Viroel FJM; Laboratory of Toxicological Research, University of Sorocaba (Uniso), Sorocaba, São Paulo, Brazil.
  • Hataka A; Department of Veterinary Clinical Sciences, School of Veterinary Medicine and Animal Science, São Paulo State University (UNESP), Botucatu, São Paulo, Brazil.
  • Grotto D; Laboratory of Toxicological Research, University of Sorocaba (Uniso), Sorocaba, São Paulo, Brazil.
J Biomed Mater Res B Appl Biomater ; 106(5): 1799-1808, 2018 07.
Article em En | MEDLINE | ID: mdl-28902456
Two scaffolds of chitosan/sodium alginate/hydroxyapatite (Ch/NaAlg/Hap) 1:1:0.2 and 1:1:0.6 were evaluated in the prevention of bisphosphonate-induced jaw osteonecrosis. Two groups of rats (n = 24, according to the euthanasia time: 15 or 30 days after the last Zoledronic acid (ZA) administration) were subdivided in four subgroups (n = 6): I - Control (saline + teeth extraction); II - ZA 0.6 mg/kg + teeth extraction; III - ZA + teeth extraction + scaffold 1:1:0.2; IV - ZA + teeth extraction + scaffold 1:1:0.6. Jaws were evaluated histologically and blood was evaluated for hematological and biochemical parameters. Histopathology showed significant osteonecrosis in AZ group. The scaffold's implantation, despite the inflammatory process, were able to prevent the osteonecrosis. In the 15-day euthanasia group, an increase in red blood cells and platelets was observed in the subgroup II. Hemoglobin and hematocrit decreased in subgroup IV compared to II. Hepatic transaminases and creatinine concentration increased significantly in subgroup II. Calcium concentration increased in subgroup IV compared to II. In the 30-day euthanasia group, no differences among the groups were observed for any parameter. Scaffolds proved to be efficient and safe to liver and kidney function. Some hematological parameters were altered by the scaffold, but returned to normal concentrations over time. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1799-1808, 2018.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Durapatita / Alicerces Teciduais / Osteonecrose da Arcada Osseodentária Associada a Difosfonatos Limite: Animals Idioma: En Revista: J Biomed Mater Res B Appl Biomater Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Durapatita / Alicerces Teciduais / Osteonecrose da Arcada Osseodentária Associada a Difosfonatos Limite: Animals Idioma: En Revista: J Biomed Mater Res B Appl Biomater Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos