Your browser doesn't support javascript.
loading
Effect of Alkaline Peroxides on the Surface of Cobalt Chrome Alloy: An In Vitro Study.
Vasconcelos, Glenda Lara Lopes; Curylofo, Patricia Almeida; Raile, Priscilla Neves; Macedo, Ana Paula; Paranhos, Helena Freitas Oliveira; Pagnano, Valeria Oliveira.
Afiliação
  • Vasconcelos GLL; Department of Dental Materials and Prosthesis, USP School of Dentistry of Ribeirao Preto, Brazil.
  • Curylofo PA; Department of Dental Materials and Prosthesis, USP School of Dentistry of Ribeirao Preto, Brazil.
  • Raile PN; Department of Dental Materials and Prosthesis, USP School of Dentistry of Ribeirao Preto, Brazil.
  • Macedo AP; Department of Dental Materials and Prosthesis, USP School of Dentistry of Ribeirao Preto, Brazil.
  • Paranhos HFO; Department of Dental Materials and Prosthesis, USP School of Dentistry of Ribeirao Preto, Brazil.
  • Pagnano VO; Department of Dental Materials and Prosthesis, USP School of Dentistry of Ribeirao Preto, Brazil.
J Prosthodont ; 28(1): e337-e341, 2019 Jan.
Article em En | MEDLINE | ID: mdl-29573505
PURPOSE: Removable denture hygiene care is very important for the longevity of the rehabilitation treatment; however, it is necessary to analyze the effects that denture cleansers can cause on the surfaces of prostheses. Thus, this study evaluated the effect of alkaline peroxide-effervescent tablets on the surface of cobalt-chromium alloys (Co-Cr) used in removable partial dentures. MATERIALS AND METHODS: Circular metallic specimens (12 × 3 mm) were fabricated and were immersed (n = 16) in: control, Polident 3 Minute (P3M), Steradent (S), Efferdent (E), Polident for Partials (PFP), and Corega Tabs (CT). The surface roughness (µm) (n = 10) was measured before and after periods of cleanser immersion corresponding to 0.5, 1, 2, 3, 4, and 5 years. Ion release was analyzed (n = 5) for Co, Cr, and molybdenum (Mo). Scanning electron microscopy (SEM) analysis and an Energy-dispersive X-ray spectroscopy (EDS) were conducted in one specimen. The surface roughness data were statistically analyzed (α = 0.05) with the Kruskal-Wallis test to compare the solutions, and the Friedman test compared the immersion durations. Ion release analysis was performed using 2-way ANOVA and Tukey's test. RESULTS: There was no significant surface roughness difference when comparing the solutions (p > 0.05) and the immersion durations (p = 0.137). Regarding ion release (µg/L), CT, E, and control produced a greater release of Co ions than S (p < 0.05). CT produced a greater release of Cr ions than control, S, and P3M (p < 0.05). Finally, E caused the greatest release of Mo ions (p < 0.05). SEM confirmed that the solutions did not damage the surfaces and EDS confirmed that there were no signs of oxidation. CONCLUSION: The various solutions tested did not have any deleterious effects on the Co-Cr alloy surface. Steradent, however, presented the smallest ionic release.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peróxidos / Ligas de Cromo / Materiais Dentários Idioma: En Revista: J Prosthodont Assunto da revista: ODONTOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peróxidos / Ligas de Cromo / Materiais Dentários Idioma: En Revista: J Prosthodont Assunto da revista: ODONTOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos