Your browser doesn't support javascript.
loading
Hollow-fiber renewal liquid membrane extraction coupled with 96-well plate system as innovative high-throughput configuration for the determination of endocrine disrupting compounds by high-performance liquid chromatography-fluorescence and diode array detection.
Lopes, Daniela; Dias, Adriana Neves; Merib, Josias; Carasek, Eduardo.
Afiliação
  • Lopes D; Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040-900, SC, Brazil.
  • Dias AN; Instituto Federal Catarinense, Campus Brusque, 88350-300, Brazil.
  • Merib J; Departamento de Farmacociências, Universidade Federal de Ciências da Saúde de, Porto Alegre, 90050-170, RS, Brazil.
  • Carasek E; Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040-900, SC, Brazil. Electronic address: eduardo.carasek@ufsc.br.
Anal Chim Acta ; 1040: 33-40, 2018 Dec 21.
Article em En | MEDLINE | ID: mdl-30327111
This paper describes a new configuration of the hollow fiber renewal liquid membrane (HFRLM) procedure for the high-throughput determination of the endocrine disrupting compounds 4-nonylphenol, 4-octylphenol, 4-tert-octylphenol, methylparaben, ethylparaben and bisphenol A using a 96-well plate system and high-performance liquid chromatography. In this configuration, cylindrical blades were adapted as a support for polypropylene membranes used as supported liquid membranes in the HFRLM approach. The proposed configuration exhibited important advantages including high-throughput, low solvent and sample consumption, and good analytical performance. The optimized extraction conditions were achieved with the use of a mixture comprised of 50:50 v/v 1-octanol:hexane as the supported liquid membrane, sample pH 5, extraction solvent 15 µL (hexane) and extraction time 45 min. The limits of quantification varied from 0.5 µg L-1 for 4-octylphenol to 15 µg L-1 for methylparaben and ethylparaben and the r2 ranged from 0.9908 for methylparaben to 0.9992 for 4-tert-octylphenol. HFRLM combined with the use of a 96-well plate provides an environmentally-friendly configuration. It offers good accuracy when applied to analyze water samples, with relative recoveries ranging from 72 to 130%, for 4-octylphenol and 4-nonylphenol, respectively, and precision varying from 1 to 14.3%, for 4-nonylphenol at 1.0 µg L-1 and bisphenol A at 8.0 µg L-1, respectively.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Chim Acta Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Brasil País de publicação: Holanda