Your browser doesn't support javascript.
loading
Clinical utility of intraprocedural three-dimensional integrated image guided transcatheter aortic valve implantation using novel automated computed tomography software: A single-center preliminary experience.
Butter, Christian; Kaneko, Hidehiro; Tambor, Grit; Hara, Masahiko; Neuss, Michael; Hoelschermann, Frank.
Afiliação
  • Butter C; Herzzentrum Brandenburg in Bernau bei Berlin & Medizinische Hochschule Brandenburg Theodor Fontane, Bernau, Germany.
  • Kaneko H; Herzzentrum Brandenburg in Bernau bei Berlin & Medizinische Hochschule Brandenburg Theodor Fontane, Bernau, Germany.
  • Tambor G; Herzzentrum Brandenburg in Bernau bei Berlin & Medizinische Hochschule Brandenburg Theodor Fontane, Bernau, Germany.
  • Hara M; Department of Cardiovascular Medicine, Osaka City University Graduate School of Medicine, Osaka, Japan.
  • Neuss M; Herzzentrum Brandenburg in Bernau bei Berlin & Medizinische Hochschule Brandenburg Theodor Fontane, Bernau, Germany.
  • Hoelschermann F; Herzzentrum Brandenburg in Bernau bei Berlin & Medizinische Hochschule Brandenburg Theodor Fontane, Bernau, Germany.
Catheter Cardiovasc Interv ; 93(4): 722-728, 2019 03 01.
Article em En | MEDLINE | ID: mdl-30408327
OBJECTIVES: Novel automated computed tomography (CT) software (Valve ASSIST 2) has been developed for transcatheter aortic valve implantation (TAVI), which not only provides three-dimensional (3D) reconstruction of multidetector (MD) CT images, but also enables intraprocedural real-time fusion of fluoroscopic and MDCT images. We aimed to clarify the reproducibility and accuracy of this software in the aortic annulus assessment and verify the potential of intraprocedural integrated MDCT imaging for TAVI. METHODS AND RESULTS: We examined 50 patients with severe aortic stenosis undergoing transfemoral TAVI. Aortic annulus measurements were performed using 3mensio and the novel planning software. For intraprocedural imaging, preoperative CT dataset was overlaid onto fluoroscopy with the fusion software. The two images were aligned using the aortic root anatomy visible on both modalities. Novel planning software provided excellent reproducibility for the measurement of aortic annulus area (intraobserver intraclass correlation coefficients [ICC] 0.959, interobserver ICC 0.941), and perimeter (intraobserver ICC 0.915, interobserver ICC 0.912). Excellent correlation was found between novel planning software and 3mensio (ICC 0.952 for aortic annulus area, and 0.923 for perimeter). Intraprocedural fusion image of CT aortography and fluoroscopic aortic root aortography generated by this novel software identified coronary orifices and the distribution of aortic valve calcification during the device positioning. Fusion image displayed coronary orifices after device implantation. CONCLUSIONS: Novel planning software showed excellent reproducibility and accuracy in the assessment of aortic root anatomy. Furthermore, the integrated 3D fusion image might have a potential as an intraprocedural imaging modality to contribute to the development of a safer TAVI procedure.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Calcinose / Imageamento Tridimensional / Cirurgia Assistida por Computador / Tomografia Computadorizada Multidetectores / Substituição da Valva Aórtica Transcateter Tipo de estudo: Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Calcinose / Imageamento Tridimensional / Cirurgia Assistida por Computador / Tomografia Computadorizada Multidetectores / Substituição da Valva Aórtica Transcateter Tipo de estudo: Prognostic_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Catheter Cardiovasc Interv Assunto da revista: CARDIOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Alemanha País de publicação: Estados Unidos