[Transthoracic echocardiographic assessment of cardiac output in mechanically ventilated critically ill patients by intensive care unit physicians]. / Avaliação ecocardiográfica transtorácica do débito cardíaco feita por médicos da unidade de terapia intensiva em pacientes críticos sob ventilação mecânica.
Braz J Anesthesiol
; 69(1): 20-26, 2019.
Article
em Pt
| MEDLINE
| ID: mdl-30413278
BACKGROUND AND OBJECTIVES: Transthoracic echocardiography may potentially be useful to obtain a prompt, accurate and non-invasive estimation of cardiac output. We evaluated whether non-cardiologist intensivists may obtain accurate and reproducible cardiac output determination in hemodynamically unstable mechanically ventilated patients. METHODS: We studied 25 hemodynamically unstable mechanically ventilated intensive care unit patients with a pulmonary artery catheter in place. Cardiac output was calculated using the pulsed Doppler transthoracic echocardiography technique applied to the left ventricular outflow tract in apical 5 chamber view by two intensive care unit physicians who had received a basic Transthoracic Echocardiography training plus a specific training focused on Doppler, left ventricular outflow tract and velocity-time integral determination. RESULTS: Cardiac output assessment by transthoracic echocardiography was feasible in 20 out of 25 enrolled patients (80%) and showed an excellent inter-operator reproducibility (Pearson correlation test r=0.987; Cohen's K=0.840). Overall, the mean bias was 0.03L.min-1, with limits of agreement -0.52 and +0.57L.min-1. The concordance correlation coefficient (ρc) was 0.986 (95% IC 0.966-0.995) and 0.995 (95% IC 0.986-0.998) for physician 1 and 2, respectively. The value of accuracy (Cb) of COTTE measurement was 0.999 for both observers. The value of precision (ρ) of COTTE measurement was 0.986 and 0.995 for observer 1 and 2, respectively. CONCLUSIONS: A specific training focused on Doppler and VTI determination added to the standard basic transthoracic echocardiography training allowed non-cardiologist intensive care unit physicians to achieve a quick, reproducible and accurate snapshot cardiac output assessment in the majority of mechanically ventilated intensive care unit patients.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Respiração Artificial
/
Padrões de Prática Médica
/
Débito Cardíaco
/
Ecocardiografia Doppler de Pulso
/
Cuidados Críticos
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
Pt
Revista:
Braz J Anesthesiol
Ano de publicação:
2019
Tipo de documento:
Article
País de publicação:
Brasil