Development and validation of a green method for dissolution monitoring of pharmaceutical combinations. Meloxican and pridinol.
Salazar-Rojas, Duvernis; Intilangelo, Aldana; Vignaduzzo, Silvana E; Maggio, Rubén M.
Afiliação
  • Salazar-Rojas D; Área de Análisis de Medicamentos, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario e Instituto de Química Rosario (IQUIR, CONICET-UNR), Argentina.
  • Intilangelo A; Área de Análisis de Medicamentos, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario e Instituto de Química Rosario (IQUIR, CONICET-UNR), Argentina.
  • Vignaduzzo SE; Área de Análisis de Medicamentos, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario e Instituto de Química Rosario (IQUIR, CONICET-UNR), Argentina.
  • Maggio RM; Área de Análisis de Medicamentos, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario e Instituto de Química Rosario (IQUIR, CONICET-UNR), Argentina. Electronic address: maggio@iquir-conicet.gov.ar.
J Pharm Biomed Anal ; 170: 228-233, 2019 Jun 05.
Article em En | MEDLINE | ID: mdl-30933898
The development of a chemometric method for monitoring the pharmaceutical dissolution, under green analytical chemistry principles, was reported. Meloxicam (MEL) and pridinol (PRI) were employed as a combination model. Multivariate curve resolution with alternating least squares (MCR-ALS) was proposed to resolve UV spectra of the analytes during pharmaceutical dissolution. Empowering UV-vis spectrophotometry, which is considered an economical, ecological and fast technique, but poor in terms of selectivity. The developed method was validated in accordance to ICH guidelines, fulfilling acceptance criteria for linearity (r > 0.99 in the ranges 3.5-19.6 mg L-1 and 0.81-5.41 mg L-1 for MEL and PRI, respectively), accuracy (96.3% and 100.6% recoveries for MEL and PRI respectively), and precision (RSD < 10%) were evaluated using an independent validation set. Using a commercial sample, the method's accuracy was evaluated against HPLC analysis. Dissolution profiles were obtained using both methods. A point-to-point comparison with Moore and Flanner's factors (f1 and f2) were calculated. Specificity was evaluated by spectral correlation (R2>0.950). Additionally, the developed method works on-line and forgoes organic solvents and dilutions, lending itself to automation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piperidinas / Meloxicam Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Argentina País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Piperidinas / Meloxicam Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: J Pharm Biomed Anal Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Argentina País de publicação: Reino Unido