Your browser doesn't support javascript.
loading
Electrochemical degradation of the antibiotic ciprofloxacin in a flow reactor using distinct BDD anodes: Reaction kinetics, identification and toxicity of the degradation products.
Wachter, Naihara; Aquino, José Mario; Denadai, Marina; Barreiro, Juliana C; Silva, Adilson José; Cass, Quezia B; Bocchi, Nerilso; Rocha-Filho, Romeu C.
Afiliação
  • Wachter N; Departamento de Química, Universidade Federal de São Carlos, C.P. 676, 13560-970 São Carlos, SP, Brazil.
  • Aquino JM; Departamento de Química, Universidade Federal de São Carlos, C.P. 676, 13560-970 São Carlos, SP, Brazil.
  • Denadai M; Departamento de Química, Universidade Federal de São Carlos, C.P. 676, 13560-970 São Carlos, SP, Brazil.
  • Barreiro JC; Instituto de Química de São Carlos, Universidade de São Paulo, Av. João Dagnone 1100,Ed. Química Ambiental, 13563-120 São Carlos, SP, Brazil.
  • Silva AJ; Departamento de Engenharia Química, Universidade Federal de São Carlos, C.P. 676, 13560-970 São Carlos, SP, Brazil.
  • Cass QB; Departamento de Química, Universidade Federal de São Carlos, C.P. 676, 13560-970 São Carlos, SP, Brazil.
  • Bocchi N; Departamento de Química, Universidade Federal de São Carlos, C.P. 676, 13560-970 São Carlos, SP, Brazil.
  • Rocha-Filho RC; Departamento de Química, Universidade Federal de São Carlos, C.P. 676, 13560-970 São Carlos, SP, Brazil. Electronic address: romeu@ufscar.br.
Chemosphere ; 234: 461-470, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31228848
The performances of distinct BDD anodes (boron doping of 100, 500 and 2500 ppm, with sp3/sp2 carbon ratios of 215, 325, and 284, respectively) in the electrochemical degradation of ciprofloxacin - CIP (0.5 L of 50 mg L-1 in 0.10 M Na2SO4, at 25 °C) were comparatively assessed using a recirculating flow system with a filter-press reactor. Performance was assessed by monitoring the CIP and total organic carbon (TOC) concentrations, oxidation intermediates, and antimicrobial activity against Escherichia coli as a function of electrolysis time. CIP removal was strongly affected by the solution pH (kept fixed), flow conditions, and current density; similar trends were obtained independently of the BDD anode used, but the BDD100 anode yielded the best results. Enhanced mass transport was achieved at a low flow rate by promoting the solution turbulence within the reactor. The fastest complete CIP removal (within 20 min) was attained at j = 30 mA cm-2, pH = 10.0, and qV = 2.5 L min-1 + bypass turbulence promotion. TOC removal was practically accomplished only after 10 h of electrolysis, with quite similar performances by the distinct BDD anodes. Five initial oxidation intermediates were identified (263 ≤ m/z ≤ 348), whereas only two terminal oxidation intermediates were detected (oxamic and formic acids). The antimicrobial activity of the electrolyzed CIP solution was almost completely removed within 10 h of electrolysis. The characteristics of the BDD anodes only had a marked effect on the CIP removal rate (best performance by the least-doped anode), contrasting with other data in the literature.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Ciprofloxacina / Eletrólise Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Chemosphere Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Ciprofloxacina / Eletrólise Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Chemosphere Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido