Your browser doesn't support javascript.
loading
Development of in-house materials for the verification of specific gravity measurements: Homogeneity, stability, and proficiency studies.
Velasco-Bejarano, Benjamín; Mercado, Karina; Camacho, Evangelina; Rodríguez, Leonardo; Gómez-Pliego, Raquel; Méndez, Eradio A.
Afiliação
  • Velasco-Bejarano B; Laboratorio Nacional de Prevención y Control del Dopaje-CONADE, Ciudad de México, C.P. 14060, Mexico.
  • Mercado K; Departamento de Ciencias Químicas, Sección de Química Orgánica, Facultad de Estudios Superiores Cuautitlán-UNAM, Cuautitlán Izcalli, Estado de México, C.P. 54740, Mexico.
  • Camacho E; Laboratorio Nacional de Prevención y Control del Dopaje-CONADE, Ciudad de México, C.P. 14060, Mexico.
  • Rodríguez L; Laboratorio Nacional de Prevención y Control del Dopaje-CONADE, Ciudad de México, C.P. 14060, Mexico.
  • Gómez-Pliego R; Laboratorio Nacional de Prevención y Control del Dopaje-CONADE, Ciudad de México, C.P. 14060, Mexico.
  • Méndez EA; Departamento de Ciencias Biológicas, Sección de Ciencias de la Salud Humana, Facultad de Estudios Superiores Cuautitlán-UNAM, Cuautitlán Izcalli, Estado de México, C.P. 54740, Mexico.
Drug Test Anal ; 11(9): 1302-1307, 2019 Sep.
Article em En | MEDLINE | ID: mdl-31243893
We developed and evaluated the properties of in-house urine reference materials for the verification of laboratory refractometers, which are frequently used in clinical chemistry and doping testing laboratories. Urine was gathered from 26 healthy volunteers (16 male 30 ± 5 years old and 10 female 29 ± 4 years old), from which two urine batches were obtained: one with a low specific gravity (1.012± 0.003) and the other with a high specific gravity (1.027 ± 0.003). Homogeneity studies were conducted over 20 consecutive days. For short-term stability studies, aliquots of both urine batches were stored at -20 ± 2°C; 3 ± 2°C; 20 ± 2°C; 45 ± 2°C for 0, 2, 7, 14 and 35 days, under both light and dark conditions. Similarly, another study was conducted to measure the long-term stability of urine at -20 ± 2°C, over a 24-month evaluation period. Our data showed that the urine was homogeneous and stable at -20 ± 2°C, 3 ± 2°C, 20 ± 2°C, and 45 ± 2°C under both light and dark conditions. In all cases, the urine was evaluated by specific gravity and no statistically significant differences (p ≤ 0.05) were recorded. Additionally, a proficiency test was conducted in collaboration with 15 ISO/IEC 17025 accredited laboratories, and z-scores and performance factors were evaluated. These data indicate that this material could be used for the verification of refractometers.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refratometria / Urina / Urinálise Limite: Adult / Female / Humans / Male Idioma: En Revista: Drug Test Anal Assunto da revista: FARMACOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: México País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refratometria / Urina / Urinálise Limite: Adult / Female / Humans / Male Idioma: En Revista: Drug Test Anal Assunto da revista: FARMACOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: México País de publicação: Reino Unido