Your browser doesn't support javascript.
loading
An alternative methodology to determine 210Pb activity soil profiles.
Montes, M L; Rizzoto, M G; Ayub, J Juri; Torres Astorga, R; Taylor, M A.
Afiliação
  • Montes ML; IFLP- CONICET- CCT La Plata, CC 67, Diagonal 113 y 64, 1900, La Plata, Argentina; Facultad de Ciencias Exactas, Universidad Nacional de La Plata, Argentina. Electronic address: lmontes@fisica.unlp.edu.ar.
  • Rizzoto MG; Instituto de Matemática Aplicada San Luis, UNSL/CONICET, Ejercito de los Andes 950, Argentina.
  • Ayub JJ; Instituto de Matemática Aplicada San Luis, UNSL/CONICET, Ejercito de los Andes 950, Argentina; Departamento de Bioquímica y Ciencias Biológicas - Facultad de Química, Bioquímica y Farmacia - Universidad Nacional de San Luis, Argentina.
  • Torres Astorga R; Instituto de Matemática Aplicada San Luis, UNSL/CONICET, Ejercito de los Andes 950, Argentina.
  • Taylor MA; IFLP- CONICET- CCT La Plata, CC 67, Diagonal 113 y 64, 1900, La Plata, Argentina; Departamento de Ciencias Básicas, Facultad de Ingeniería - Universidad Nacional de La Plata, Argentina.
J Environ Radioact ; 208-209: 105998, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31255900
Unsupported 210Pb (Pbexc) is generated in air and is subsequently deposited on soil surface. The Pbexc can be used for sediment dating, soil erosion/sedimentation and air mass studies. In many cases, 210Pb activity determination (gamma ray 46.5 keV) cannot be performed due to the lack of efficiency calibration curve, especially when radioactive patron source is not available. This work presents an alternative methodology to obtain the 210Pb activity values, based on the activity definition and the attenuation coefficient determinations and assuming that soil samples coming from depth higher than 25 cm only contain 210Pb generated in the soil (Pbexc free, i.e., for those soil layers the 210Pb activity is equal to the 226Ra activity, at secular equilibrium). The proposed methodology was evaluated using soils from La Plata region, Argentina. The same soil samples were also analyzed in a second laboratory by the conventional methodology. The obtained results indicated that the proposed procedure can be used as a good alternative in cases where a calibration sample is not available.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Radioativos do Solo / Radioisótopos de Chumbo / Monitoramento de Radiação País/Região como assunto: America do sul / Argentina Idioma: En Revista: J Environ Radioact Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2019 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Radioativos do Solo / Radioisótopos de Chumbo / Monitoramento de Radiação País/Região como assunto: America do sul / Argentina Idioma: En Revista: J Environ Radioact Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2019 Tipo de documento: Article País de publicação: Reino Unido