Your browser doesn't support javascript.
loading
The role of TiO2 nanotube surface on osseointegration of titanium implants: Biomechanical and histological study in rats.
Alves-Rezende, Maria C R; Capalbo, Letícia C; De Oliveira Limírio, João P J; Capalbo, Bruna C; Limírio, Pedro H J O; Rosa, Jorge L.
Afiliação
  • Alves-Rezende MCR; Department of Dental Materials and Prosthodontics, Sao Paulo State University (UNESP), Araçatuba, Brazil.
  • Capalbo LC; Department of Dental Materials and Prosthodontics, Sao Paulo State University (UNESP), Araçatuba, Brazil.
  • De Oliveira Limírio JPJ; Department of Dental Materials and Prosthodontics, Sao Paulo State University (UNESP), Araçatuba, Brazil.
  • Capalbo BC; Department of Dental Materials and Prosthodontics, Sao Paulo State University (UNESP), Araçatuba, Brazil.
  • Limírio PHJO; Integrated Dental Clinic Program, Faculty of Dentistry, Federal University of Uberlândia, Brazil.
  • Rosa JL; Lorena School of Engineering, Sao Paulo University, USP, Lorena, Brazil.
Microsc Res Tech ; 83(7): 817-823, 2020 Jul.
Article em En | MEDLINE | ID: mdl-32227674
The nanoscale surface of titanium has been studied to improve the cellular recognition of the biological microenvironment and to increase bone-implant interaction. The aim of this study was to analyze the effect of a titanium oxide (TiO2 ) nanotube surface with a machined surface on osseointegration tibia implants without primary stability. This study used an experimental design, divided into two groups (n = 16): commercially pure titanium machined implants (Cp-Ti Ma) and commercially pure titanium anodized implants (Cp-Ti An). Titanium nanotubes were produced by anodic oxidation, and the topography of surface was analyzed using field emission scanning microscope (FE-SEM). The implants (2.1 × 2.8 mm Ø) were surgically placed in the right tibia (defects with milling drill 2.5 × 3.2 mm Ø) of 32 Wistar male rats (250-300 g). The animals were euthanized at 7 weeks postoperatively. The maximum value of removal torque was measured (N/cm) in the right tibia half of each group (8 animals/8 tibiae); the other half of each group underwent a nondecalcified protocol, stained with Stevenel blue/Alizarin red, and the formation of bone tissue in close contact to the implant was measured. The obtained data were analyzed statistically (t test). Differences were considered statistically significant for α < 0.05. Cp-Ti An implants were significantly higher in removal torque and peri-implant bone healing compared with Cp-Ti Ma implants (p < .01). Within the limitations of this study, it was observed that the surface modification of titanium by anodization (TiO2 nanotubes) can improve osseointegration, and this may be very useful to reduce the time required for peri-implant bone formation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteogênese / Próteses e Implantes / Estresse Mecânico / Tíbia / Titânio / Osseointegração Limite: Animals Idioma: En Revista: Microsc Res Tech Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteogênese / Próteses e Implantes / Estresse Mecânico / Tíbia / Titânio / Osseointegração Limite: Animals Idioma: En Revista: Microsc Res Tech Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos