Patient motion in thallium-201 myocardial SPECT imaging. An easily identified frequent source of artifactual defect.
Friedman, J; Berman, D S; Van Train, K; Garcia, E V; Bietendorf, J; Prigent, F; Rozanski, A; Waxman, A; Maddahi, J.
Afiliação
  • Friedman J; Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, California 90048.
Clin Nucl Med ; 13(5): 321-4, 1988 May.
Article em En | MEDLINE | ID: mdl-3260547
Because Tl-201 SPECT requires that patients remain in an awkward position for a prolonged time, patient motion is a potentially serious source of artifactual defects on tomographic reconstructions. Thus, a simple method was developed for detection and correction of motion from SPECT images using a Co-57 point source placed on the lower anterior chest, an area remaining in the camera's field of view throughout imaging. In the absence of motion, this point source inscribes a straight line on planar summation of the 32 projections over 180 degrees. Movement is detected by deviation from this line. The number of pixels of motion is used to shift images so that the resultant images of the point source are linear. The method of motion detection and correction was tested in 48 consecutive patients undergoing Tl-201 SPECT. The corrected and uncorrected images were reconstructed and long and short axis tomographic cuts were quantitatively analyzed using circumferential profiles of maximal counts with comparison to the lower limits of normal. Motion was detected in eight of 48 patients (17%). The amount of motion was 2 pixels in three patients and 1 pixel in five patients. Quantitative defect extent was less after correction in seven of eight patients, with a mean decrease of 71% in patients with 2 pixel motion and 44% in patients with 1 pixel motion. This corresponded with a definite reduction in the size of the tomographic defect by visual analysis, and closer resemblance to quantitatively analyzed planar images performed either before or after tomography in the same patient.(ABSTRACT TRUNCATED AT 250 WORDS)
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos de Tálio / Tomografia Computadorizada de Emissão / Doença das Coronárias / Coração / Movimento Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Nucl Med Ano de publicação: 1988 Tipo de documento: Article País de publicação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos de Tálio / Tomografia Computadorizada de Emissão / Doença das Coronárias / Coração / Movimento Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Nucl Med Ano de publicação: 1988 Tipo de documento: Article País de publicação: Estados Unidos