Your browser doesn't support javascript.
loading
Influence of rain events on the efficiency of a compact wastewater treatment plant: a case study on a university campus aiming water reuse for agriculture.
Albornoz, Louidi Lauer; Centurião, Tiago Carrard; Giacobbo, Alexandre; Zoppas-Ferreira, Jane; Bernardes, Andréa Moura.
Afiliação
  • Albornoz LL; Post-Graduation Program in Mining, Metallurgical and Materials Engineering (PPGE3M), Federal University of Rio Grande do Sul (UFRGS), Av. Bento Gonçalves n. 9500, Porto Alegre, CEP: 91.509-900, Brazil. louidi.lauer@ufrgs.br.
  • Centurião TC; LADETEC, IPH, Federal University of Rio Grande do Sul (UFRGS), Av. Bento Gonçalves n. 9500, Porto Alegre, CEP: 91.509-900, Brazil. louidi.lauer@ufrgs.br.
  • Giacobbo A; LADETEC, IPH, Federal University of Rio Grande do Sul (UFRGS), Av. Bento Gonçalves n. 9500, Porto Alegre, CEP: 91.509-900, Brazil.
  • Zoppas-Ferreira J; Post-Graduation Program in Mining, Metallurgical and Materials Engineering (PPGE3M), Federal University of Rio Grande do Sul (UFRGS), Av. Bento Gonçalves n. 9500, Porto Alegre, CEP: 91.509-900, Brazil.
  • Bernardes AM; Post-Graduation Program in Mining, Metallurgical and Materials Engineering (PPGE3M), Federal University of Rio Grande do Sul (UFRGS), Av. Bento Gonçalves n. 9500, Porto Alegre, CEP: 91.509-900, Brazil.
Environ Sci Pollut Res Int ; 27(33): 41350-41360, 2020 Nov.
Article em En | MEDLINE | ID: mdl-32683624
In this study, the efficiency of contaminant removal from a compact wastewater treatment plant (CWTP) in a university campus under different rain conditions was evaluated. Wastewater samples were collected weekly for 1 year and the physicochemical parameters were monitored. Removal efficiency higher than 77%, reaching values above 95% for samples with lower wastewater flow rates, was found for biological oxygen demand (BOD) and total and fecal coliforms. The pH values remained in the range of 6.0-8.0. However, pH values below 6.8 impaired the nitrification rate and, therefore, the removal of total Kjeldahl nitrogen (TKN) and ammonia was lower than the expected, with concentration values above those set by the Brazilian regulation for wastewater discharge. The results show that the flow rate of wastewater at the entrance of the CWTP is directly related to the rain events, thus affecting its efficiency, mainly in the removal of total solids, turbidity, and organic matter. The assessment of the treated wastewater reuse on site for agricultural purposes showed to be a prominent and more sustainable alternative regarding the discharge of wastewater into water bodies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Purificação da Água / Águas Residuárias País/Região como assunto: America do sul / Brasil Idioma: En Revista: Environ Sci Pollut Res Int Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Purificação da Água / Águas Residuárias País/Região como assunto: America do sul / Brasil Idioma: En Revista: Environ Sci Pollut Res Int Assunto da revista: SAUDE AMBIENTAL / TOXICOLOGIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha