Your browser doesn't support javascript.
loading
Could both intrinsic and extrinsic iodine be successfully suppressed on virtual non-contrast CT images for detecting thyroid calcification?
Park, Arim; Lee, Young Hen; Seo, Hyung Suk.
Afiliação
  • Park A; Department of Radiology, Ansan Hospital, Korea University College of Medicine, 123, Jeokgeum-ro, Danwon-gu, Ansan-si, Gyeonggi-do, 15355, Republic of Korea.
  • Lee YH; Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
  • Seo HS; Department of Radiology, Ansan Hospital, Korea University College of Medicine, 123, Jeokgeum-ro, Danwon-gu, Ansan-si, Gyeonggi-do, 15355, Republic of Korea. younghen@korea.ac.kr.
Jpn J Radiol ; 39(6): 580-588, 2021 Jun.
Article em En | MEDLINE | ID: mdl-33506433
PURPOSE: Although virtual non-contrast (VNC) successfully removes iodinated contrast, uncertainty exists regarding the feasibility of VNC to suppress iodine for detecting thyroid calcification. Therefore, we evaluated whether both intrinsic and extrinsic iodine attenuation were suppressed on VNC images. MATERIAL AND METHODS: We enrolled 128 patients (male: female 17:111; age 48.0 ± 10.4 years) who underwent dual-layer dual-energy CT (DL-DECT) examination before their thyroid cancer surgeries. Two additional sets of VNC (VNCu, VNCc) images were retrospectively generated from their true unenhanced (TUE) and true contrast-enhanced (TCE) series. We compared CT attenuation values measured on the VNCu and VNCc images by drawing identical regions of interest encompassing thyroid parenchyma, then subjectively determined the concordance of calcification. RESULTS: Although CT attenuation discrepancies between the VNCu and VNCc were significant (2.0 ± 5.7HU, p < 0.001),61.7%, 89.1%, and 100.0% of all measurements were < 5HU, < 10HU, and < 15HU. Based on Bland-Altman analysis, the limits of agreement were - 9.2HU and 13.2HU, whereas the proportional differences were small for VNC images generated from both TUE and TCE images. There was no discordance between two VNC image sets in detecting thyroid calcification. CONCLUSIONS: VNC technique could be a feasible method to suppress both intrinsic and extrinsically administered iodine for detecting thyroid calcification.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças da Glândula Tireoide / Calcinose / Tomografia Computadorizada por Raios X / Iodo Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Jpn J Radiol Assunto da revista: DIAGNOSTICO POR IMAGEM / RADIOLOGIA / RADIOTERAPIA Ano de publicação: 2021 Tipo de documento: Article País de publicação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças da Glândula Tireoide / Calcinose / Tomografia Computadorizada por Raios X / Iodo Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Jpn J Radiol Assunto da revista: DIAGNOSTICO POR IMAGEM / RADIOLOGIA / RADIOTERAPIA Ano de publicação: 2021 Tipo de documento: Article País de publicação: Japão